The ignore Connectivity in Server Arbitration is set to (N)
With (n) in that field I get that message ( Cannot remove; Must have at least one IPSI monitored by Server Arbitration )
I tried to put a (y) and I get (Must have at least one IPSI monitored by Server Arbitration)
Hey Guys,
Sort of stumped on this one.
I am down to the IPSI board , last board on the Gateway.
I have busied the board out and when I try to removed the IPSI board it tells me ( Cannot remove; Must have at least one IPSI monitored by Server Arbitration.)
Not sure what that message means.
I...
Helo everyone,
Need some help.....
I have an office that has 2 G700 Media-Gateways. I need to remove one of the Gateways. They looked to be in a stack configuration. We are replacing Digital phones with IP phones.
I have removed one of the Gateways. I removed the translations from the 2 digital...
Great command thanks.
I think we just found the problem:
02 goto step 50 if calls-queued for skill x pri h > 50
10 queue-to skill xxx pri m
50 disconnect after announcement xxxxx
in the first step we had the pri set to h
in the 10th step the queue-to skill pri was set to m
we set both to...
I just posted the below, also. This is dealing with the above thread.
Maybe one of you could help.
I am trying to accomplish this with the command:
02 goto step 50 if calls-queued for skill x pri h > 50
50 disconnect after announcement xxxxx
The problem I am having is:
In the command...
I have a vector that has been programed to receive calls;
In this vector, I have it queueing to a skill.
I would like to cap the callers at 50 that is in the queue at one time.
I am trying to accomplish this with the command:
02 goto step 50 if calls-queued for skill x pri h > 50
50...
I have a question guys.
I hope I am asking this right.
I have programmed a vector that is a call menu:
When someone calls the VDN( which is a DID ).
It will collect collect a digit after an announcement, the announcement will give the caller,
lets say, 2 options. If the caller hits a 1 or 2...
I have a problem:
I have a media gateway that has 3 pots lines coming into the gateway. we have setup a trunk group for those 3 pots and they work fine. We added an extra pots line to the MG. We have a digital station 6408 D+ attached to the MG. We have created a trunk group for that extra pots...