Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mitelritz

    miVoice API or httpPost or DB query event. mcd

    Is there any way to outside of GUI on the miVoice in todays world. due to the immediate need this has to be somewhat automated due to way this is setup. like API / DB query update/ ODBC. Im doing some deep dive digging now. basic example update system speed call 1144 to a different...
  2. mitelritz

    smdr call records to Syslog server also / possible

    Ohh thats cool with the ftp server but no syslog server cause id hate to build something with telnet always open not sure how long it will stay open before i might lose data or not but htinking if there was a syslog method that would help alot but FTP in mcd5 seems cool we have alot of customers...
  3. mitelritz

    smdr call records to Syslog server also / possible

    Howdy im checking to see instead of just keeping a telnet port open in a script where i will build to get the call records. Can i just point to a syslog server and then have it that way But will it also still keep it on the 3300 logs
  4. mitelritz

    Sx-2000 Connecting T1 to Shoretel

    digital E&M does that mean i chose in the Trunk assignment form 6 AND 6 for Digital Link descriptor Thanks i know its like the 3300 but its a tad confusing if i dont see all numbers in the gui
  5. mitelritz

    Sx-2000 Connecting T1 to Shoretel

    now is there set or if i use Digital E&M are their easy settings to adjust for that only reason why i ask is because i tried putting the descriptor of 2 and it said serious System Error Thanks
  6. mitelritz

    Sx-2000 Connecting T1 to Shoretel

    i get kind of confused in the Trunk assignment FORM where it says Circuit Descriptor. Does that mean i use the DIGITAL link descriptor where i put the T1D4 and such or do i use the one that says Digital E and M circuit descriptor thanks
  7. mitelritz

    Sx-2000 Connecting T1 to Shoretel

    How would i go about doing so.... I have tried many different things.. it shows up as a Universal T1 (DS1/T1 II FORMATTER CARD) i see them idle i have tried many different things but not sure WHAT to program it as right now i have it as a MSDN/DPNSS what does it need to be and if it...
  8. mitelritz

    MITEL SIP Trunking to SIP provider

    yea that was my final outcome on what i did i put it to 0 i was gonna say if that was it 0 is your answer cool .... out of curiousity who is your provider (is it telecentri) you are dealing with (we dealt with alot of providers trying to pick best of the best) thing i learned mitel and the...
  9. mitelritz

    MITEL SIP Trunking to SIP provider

    Hey there just a thought In the sip world theres alot of different things Try and lower your session time (seems it might be at 300) and see if you lower it it could lower ur disconnect time.. one of my issues were a cust session timer was at 600 and the call would always disconnect at 5...
  10. mitelritz

    5312 handsets cutting off calls

    hey hey i had about the same issue but it was on a 200icp platform and i see alot of issues on the 3300 line. talked with a guy at support and he told me firmware 2.1.0.29 was the fix for the phones on the 3300 but you know how support goes sometimes :) . in my case i upgraded the 200icp to 5...
  11. mitelritz

    5312 handsets cutting off calls

    i Put 2 different switches hp and a linksys and i notice that it didnt do anything (seems like the more they use the phone the more it shows) now my setup is using a sx 200 icp it kinda tells me that this could be a firmware bug on the phone or either a bug on the system but my phones reboot...
  12. mitelritz

    MITEL SIP Trunking to SIP provider

    sory and if your not registering with a provider (direct ip authentication) in your network assignment form.. take out the ip addess in SIP registrar FQDN or ip address entry if seen that issue on my end come up. (IF YOUR Doing direct ip Authenication) (and not registering with a user/pass)...
  13. mitelritz

    MITEL SIP Trunking to SIP provider

    ive had that error before and it was a setup message of the trunks (trying running a wireshark and see what code you get when making the call. and ask what SBC your Provider has. i tend to see mitel and the Nextone not to be friendly. Thanks
  14. mitelritz

    Mics Manual

    is there a good place to find like a manual of the termination and what each card does in the main Cabinet just really curious on why my paticualr system or maybe all i have the first 25 pair on 24 ext then the 2nd on 6ext and 2 vm ports kind of confusing but i couldnt find something in...
  15. mitelritz

    Mics PRI possible ?

    never mind i found it ... Thanks
  16. mitelritz

    Mics PRI possible ?

    i tried registering on nortel but im assuming only (vars/ dealers would probabally have acces to it...) thanks
  17. mitelritz

    Mics PRI possible ?

    is it even possible to get NRU --- would i have to get a newer version or will 10.0 work.. if so where could i get it.... Thanks
  18. mitelritz

    Mics PRI possible ?

    if its possibile do i need to upgrade from mics 4.0 and if i do would i lost my Database do i need to get a pri enabler code, service card , PRI card Thanks
  19. mitelritz

    Mics additional Station Cards

    so being i got a M12x0 and i want to add 12 more extensions would i have to replace that with a Different type of bay
  20. mitelritz

    Mics additional Station Cards

    Okay I might need to look at a manual but I went to site And they have A modular mics. With an expansion bay that shows it as M12XO which tells me I can't use that for extensions at all seems like only pots lines But they Do need 12 exts. So do I have to changeout that to like a combo bay...

Part and Inventory Search

Back
Top