Thank you both for the quick response.
The FAX...It is a DDI DN Yes
I don't know for sure can you tell me how to check to make sure it's a DDI?
Changing CLS = FAXA did not work. I changed that on the analog DN or the I2004 DN?
I will have her try forwarding the I2004 to the extension of...
OK here's the skinny, our CP voicemail system went down, with no support from vendor I needed a solution very quickly and created an analog DN and hooked up an el-cheapo answering machine.
I changed the hunt DN on the main number (x5960) to go to the newly created analog DN. The answering...
I need to move a callpilot system from one location to another and need to hire a tech in the Fort Wayne, IN area.
Both locations have Nortel optn 11. One is analog and one is digital phones. All programming on the CP is done, I just need it moved.
mrice(at)cbrwg.com
TIA
Here's what the vendor found:
CLS smwa was not set.
Secondary Message Waiting.
I should have posted the TN. We could have gotten it resolved sooner.
Thanks to all of you who posted and helped.
Forgive my ignorance. Is the AC1 the number that would be pressed to dial a call? If yes then yes I've added then 9 in front of the 10 digits in the users CP MB. So CP would see 9xxxxxx5820 with the same results.
If no the AC1 is not that number then what do I do to find the AC1 number...
GHTROUT, nope that didn't solve it either.
However, when dialing the direct DID number 416-0717 it does work. I think it's still at the CO level as stated by tnphoneman.
OK our provider doesn't "translate" that number. Is there a way to strip the clid of that number.
As I said in my initial post the clid comes through as (xxx)xxx-5820. It actually comes into the PRI as xxx-0717 and then IDC to extension 8411. Is there a way I can completely strip the 8520...
Yes that's how I searched.
I turned on msgi and called the number and it gets translated into another DID number. That DID goes to 8411. Another call to my provider to find out if they convert that number for me. Will post back when I know more.
Sorry, I missed that detail. If I take it out of IDC it still goes to 8411. I tried re-routing using IDC to my extension and it still rang on the other extension.
Hello all,
Opt 11C
CallPilot 2.i
Here is the situation. I have a number that I believe is programmed to the PRI. (xxx)xxx-5820. It comes in and rings on the users phone on key 3 extension 8411. I have searched for 8411 and it is not a TN or ACD. How else could this be programmed?
When I...
Hello all,
I have 11 Ricoh Aficio 4500c printers all spread out in four buildings connected on a WAN. These printers allow me to create different users on each machine... The problem is I have to create users on each machine. Anyone no of a good User Management tool for multiple printers...
I was experiencing the same issue. Did the ACD and it worked properly. Now that the work around is fixed, what would cause something that was working quite normally for several years to just stop working one day and for only this user?
While in the testing processing the extension was...
So here is my next question.
I've got the above working thanks to BigIndian, now I need to move 4 more extensions the same way. I don't want to build physical phones but have them appear on the newly built 8417. What are your recommendations?
Thanks again BigIndian. I have read hundreds of...
No, I built the 84XX on the receiving end that dsc points to.
I just can't seem to key the 3903 programmed with that dn of 8417.
So do I need to out the dsc in site 2 where I want the DN to show up? If so, how?
TIA
Here is the post of the TN is site 2:
REQ: prt
TYPE: tnb
TN 25 0
DATE
PAGE
DES
DES 8417
TN 025 0 00 00
TYPE 3903
CDEN 8D
CUST 0
FDN 8580
TGAR 1
LDN NO
NCOS 4
SGRP 0
RNPG 0
SCI 0
SSU 0000
LNRS 16
XLST
SCPW 6740
CLS CTD FBD WTA LPR MTD FNA HTA TDD HFA GRLD CRPD STSD
MWA LMPN...
OK Here goes,
3 locations all opt11
outed tn to cdp from location 1 to location 2
ld 87'd to create the new cdp for that extension in switch 1.
Here is the post of that
REQ prt
CUST 0
FEAT cdp
TYPE dsc
DSC 8417
DSC 8417
FLEN 0
DSP LSC
RLI 13
NPA
NXX
Built a new 3903 at site 2. (Went...