Hi !
dognbone
I think your need some extra patcher's ,
called "exdiv" patch" made for md110, bc7 version.
if your need more info ...tell every one... !
good day ..
r.b.
hi ! Gallian.
I am used parameters.
ROUTE DATA
ROU TYPE VARC VARI VARO FILTER
12 TL11 H'00000001 H'00000188 H'00000015 NO
PTS sends "Dial tone" (varo 00000015).
good day..
Hi !
---------------------------------------------
The MD110 Service Packs (CNA) is divided in a Service Pack for updating from CNA127 to CNA134, and a new Service Pack updating from CNA134 to the latest CNA.(142 bc10).
Because of the manual action in CNA134 with shifting the program unit CTLMP...
HI !
to Avstral , bc9consono
Here is full list of extdiv patch's, I don't know are they
same in every marketing area. !
maybe Ericsson take some payment for these....?
61924 EHHS2
61927 RMPS2
61943 RMPS13
61956 RMPS4
61958 TLP50
61965 RMPS2
61968 CMPS2
64270 RMPS10
64271 OLP1S1...
to
bc9 consono
Now I remember that we need some extra patch's
when we use bc9.
like: 61924 EHHS2
61927 RMPS2
61943 RMPS13
61956 RMPS4
61958 TLP50
61965 RMPS2
61968 CMPS2
64270 RMPS10
64271 OLP1S1
64272 RMPS5
64274 DERS1
64276 ELP6
64277 CMPS23
64279 DERS6
64454 CMPS3
64457...
HI !
BC9CONSONO
DIV Parameter Can,t be longer than 10 digits .
USE RODDI, PRE, TO FORMATING Out going traffic .
or abbreviated number!!
- an external number within a private network of type APNSS/DPNSS/ISDN
Hi !
robinlemerre
sorry about wrong answer..
Can you try these..
at first:
IOEQI:IODEV=SYS1,EQU=1-0-60-4,USAGE=OUT,TYPE=NETWORK;
and next.
IOEQI:IODEV=SYSMML,EQU=1-0-60-4,USAGE=MML,AUTH=7,TYPE=NETWORK;
Hi !
Your problem, was this kind:
"I have also had problems when activating the fourth port of the NIU card with the IOEQI command (usage=mml and type=network), it answers me with "NOT ACCEPTED POSITION NOT EQUIPPED".
Try to check this commands:
IOBPI:NODE=SYSN,BPOS=1-0-60...
Hi susip
Try these commands.
----
EXTEI:DIR=865,EQU=1-1-60-14,TYPE=EL6,CAT=3,CUST=2,ICAT=0018,TRM=0,ADC=000000000;
EXTEI:DIR=866,EQU=1-1-60-15,TYPE=EL6,CAT=3,CUST=2,ICAT=0018,TRM=0,ADC=000000000;
GHGRI:GRP=890,SERV=5000,TRAF=15,SEL=110,QUE=2,LIM=1,RLTC=0;
GHGMI:GRP=890,DIR=865...
Hi !
TAU D is a Terminal Adapter Unit designed for connection to the Ericsson exchanges ASB 501 and ASB 150 or equivalent and allows voice transmission and signal channel access over the two wire digital extension line 2B+D. It is intended for connection of OWS, Application link, PSC or...
Hi
You can check following settings.!!
opcgs , Operator call origin group set
opcts, Operator call type data set
RODNI Route day and night number initiate
here is some example, listing from md bc 7.2
CALENDAR DATA
VERSION=FIBC7.2A/CORR3
11:50:42
05 JUL 2002
<OPDDP:DIR=ALL;
OPERATOR...
hi !
here is some explanation of the case ...
TRAFFIC STATE
Line-individual state for each external line.
Can be one of the following:
IDLE,
REGISTER,
BUSY,
NOPROGRESS,
CALORG (call from originator),
SPEECH,
EXLLINCON (external trunk/tie line connected,
OTGCAL (outgoing call)...
Hi !
Here is two fault code descriptions
1. Fault code description
Seize acknowledgement has not been received within stipulated time or bit b in the signalscheme = 0 before end of selection signal has been received. The fault remains until seize acknowledgement is received or when release...
Hei!
TRY command RFPUI:UNIT=TWP2,LIM=1 it is possible to deblock your port.
TWP2 Terminal program which handles the communication between IPU boards and other programs with regard to the terminal function, for example command transmission, printout transmission.
TWP3 Terminal...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.