Option11c timing is set to EXT
I've tried to change the DCH CLOK to INT but cannot get the Option11c to prompt the CLOK prompt when doing a change.
ADAN DCH 13
CTYP TMDI
CARD 05
PORT 1
DES ASTERIX
USR PRI
DCHL 5
OTBF 32
PAGE 003
PARM RS232 DTE
DRAT 64KC
CLOK EXT...
...call routing between the two working but cannot figure out the timing setup of the TIE PRI to the Asterisk box to stop SLIPs on the Option11c.
* The Option11c is receiving SLIPR on the PRI to the asterisk box if I set the Asterisk Box TIE line clocking to free.
* The Option11c is receiving...
Asterisk box has two T1 connections.
1. PRI from AT&T (AT&T provides clocking on this circuit)
TelcoB(M)--(NI2)--(C)[SPan1]Asterisk
2. PRI to Option11c (Asterisk provides clocking on ths circuit)
Asterisk[Span2](M)--(Q.SIG)--(C)[Loop5]Option11c
On the PRI to the Option11c even...
Changed DDB settings to stop maintenance counters from restarting loop5 due to SLIPD hits but I'm still taking the hits...
In a scenerio with two circuit providers how do you setup clocking on the Option11c?
Thanks...
StinkTech
I've got 6 Digial phones (4x2616 and 2xM3904) and one analog (1x500) with a MCR DN 2000 setup as a ring group. The analog line is connected to a ringer. The problem I'm having is the ringer will work 10-20 times then stay busy and no longer work. The digital phones continue to ring. If I...
janaya,
this is a rebuild of a system hit by lightning. Nothing changed on the LEC side. We were not removing the 1 prior. Plus we can not make local calls either (10 digit dialing). Again everything goes out the same rli/route with no DMI.
thanks for the prompt response...
PRI SETUP, Can Receive all, only tollfree calls go out others rng busy (fast busy). DCH monitor shows CAUSE: #41 - NTWK TEMP FAIL
Can dial toll free numbers ok, incoming works fine all others fail. LD 90 AC1 routes all tollfree and others to same rli (2) no DMI all out the same route (0)...
I've got a customer with a Legend Magic Rel7.0 A lightning storm took out the programming port. I've picked up another processor Rel7.0 processor card. I'm thinking I should be able to put the 2mb flash card in the new processor card restart the system and all should be good. Is this...
Curlycord,
Even though your site is under construction I still enjoyed it.
It was on a different network prior. I plan on taking a new Powersupply up in a couple weeks. I'll see what happens. Thanks for the input. BTW: Where are your FAQS?
Thanks,
StinkTech
CCMS 6, LM Service failed on a new install after installing SU_07. I uninstalled the LM and reinstalled. When I go to view the licenses in LM Configuration I get the following message:
CC Licenses:
No Active License Manager
After browsing and importing the license key file restarting the...
Back in early 2009 I had two servers built up without configuring them so we would have a standby ready. I guess I forgot the password used at that time.