Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Shahid Ali

    HIpath V5 Backup Error

    @sbcsu Thanks you very much .back worked but the controller 6 status changed to blocked by AMO. CONTROLLER: 6 IS ACTIVE LOAD DEVICE, LOAD AREA IS: :PDS: TYPE: HD SS-NO : <CF1G3> SIZE : 1183 MB ( 18932*64KB) GRAN : 512 AREA: A NAME : A1H6A STATUS : BLOCKED BY AMO AREA-SZ: 0 MB (2 *64KB)...
  2. Shahid Ali

    HIpath V5 Backup Error

    @Hipath4k could you please help me through commands deactivate & activate the area. Thanks
  3. Shahid Ali

    HIpath V5 Backup Error

    COPY-DDRSM:UNIT=A1, MASTERID=1, MASTERRAR=E&F, SLAVEID=6, SLAVEAR=E&F; after excecutin the below command for backup i received this Error = F11: AREA/DEVICE <:A1H6E:. HAS THE STATE <IN_SERVICE> AND CANNOT BE ACCESSED. i am not able to take Backup Kindly guide me to solve this problem in...
  4. Shahid Ali

    ERROR F4401

    Good morning dear colleagues! Please tell us who came across. I did not find errors in the manual. F4401 M8 N0709 NO ACT BPA VECO DEV DH, BAD SEIZURE 20-02-13 09:54:13 ALARM CLASS: CENTRAL: 024 CC: 65535 EC: 65535 UA: 0B24: 1FEE SP: FFFF: FFFF LD: 01-02-010-22 DT: 40 ST: 55 SN: 08C0A CEVT: 2C...
  5. Shahid Ali

    ALARM CLASS CENTRAL 027 F2102 E8 N0077

    HI ALL when I check system ( Hipath 4000 V5 ) sta-hista:search; output is <START-HISTA:RTYPE=SEARCH; START-HISTA:RTYPE=SEARCH; H500: AMO HISTA STARTED H1: 00001 ERROR MESSAGES FOUND F2102 E8 N077 NO ACT A1 IX UNIX MESSAGE 19-10-24 07:21:59 ALARM CLASS:CENTRAL:027 UNIX NAME: UNIX TIME:--------...
  6. Shahid Ali

    STMI4 Error hipath V5

    Dear all I am getting the below Message and unable to figure out what is the actual issue The STMI4 card is not connected to any device.it,s Hipath V5 F5749 E8 N2890 NO ACT BPA BOARD LW REQUEST 19-06-11 17:06:45 ALARM CLASS:CENTRAL:002 P202:LTG1 :LTG1 :LTU1 :014: 0 : 0 Q2324-X500 STMI4/1 BST:01...
  7. Shahid Ali

    Hipath 4000 V5 STMI4 Card stauts fail

    Thanks, to Moriendi and donb01 . it,s ok now.I just remioved and put it back again.
  8. Shahid Ali

    Hipath 4000 V5 STMI4 Card stauts fail

    Dear all The STMI4 card LED is red (Fail) my Boss asking the reason but i am not able to answer. after running DISP-BCSU; the card status is LTG 1 LTU 1 SRCGRP 1 ALARMNO-LTU O PEN Assigned module Module Type FCT ID SEC HWY ALARM NO INSERTED MODULE HW-STATE INFO...
  9. Shahid Ali

    paging setup hipath 4000

    Thanks Alot Xs650. ITS connected to EricssonLG PBX UCP SLTM32. Do we ineed any Configuration in Hipath 4000 for this.
  10. Shahid Ali

    paging setup hipath 4000

    yes Dear there is one LG ipecs SLTM32 ip Pbx interface is in IL Shin Paging phone system rack.
  11. Shahid Ali

    paging setup hipath 4000

    Dear We have a il Shin Korean paging phone system over loud speaker of 20 watts and 10 watts speaker. we want paging over Hipath 4000 direct wire in the building does we require any IP PABX interface.
  12. Shahid Ali

    paging setup hipath 4000

    Dear all, we have hipath 4000 v5 in our company and i want to setup paging on analog extension as well as digital extension. anyone please guide me. Regards,
  13. Shahid Ali

    Siemens Hicom 350 H to Hipath 4K - 24 * 7 online technical support

    Thanks all of you for quick response. we have two building one supplied with Hipath communication server and other with two Echo server .
  14. Shahid Ali

    Siemens Hicom 350 H to Hipath 4K - 24 * 7 online technical support

    Dear i am new to Hicom can you please tell me the differnce between Hipath 4000 communication Server and openScape 4000 Eco Server

Part and Inventory Search

Back
Top