I tried updating from 5.9.0.004 version to 5.12.6.007 that worked fine on the 4850's but when I did it to the 4826s', it will only load to the menu which gives me a Agent Code Checksum Failed. These are ancient but just want to get it back working again if possible. Thanks!
We are trying to install an Avaya IP Office 500 with PRI cards, we moved the PRI's over to the new IP Office and the new IP sets Caller ID works fine, but when passing a call from the old Nortel CS1000, the IP Office seems to strip the CallerID info and the call shows as unknown on the receiving...
I have but hopefully a simple question. Currently we have a couple remote shelves from our Nortel Meridian Option 11c PBX. I would like to get away from the rented T1's that go to both these remote shelves with fiber that we are planning to run to both these locations. What is the easiest way to...
Option 11c here. Currently we have outgoing callerID showing as our main number for all numbers, but now with 911 and having several remote sites we need to be able to show different numbers outgoing for callerID. How can I do this? Is it done by making groups and assigning outgoing callerID...
I thought about that and was wondering if there where any patch panels with the 25 pair cable connector built into it so you could just plug in a 25 pair cable with connectors on both ends and it would work, I guess it would have to be specially made for the Nortel equpment so that only 16 pairs...
I have a Option 11c that I need to move to a new building and that building is being wired with cat5e cable only. Is there a company that makes cables and patch panels that will easily connect from the 25 pair cross-connect terminal in the 11c? Has anyone tried thais and if so what did you use...
Does a NOrtel OPtion 11c ver 24.24 keep any call records, even for a limited period of time or are they thrown out as soon as they are sent to your call accounting software?
How do I make sure I am on Card 0 Port 0 for LD 143 Upgrade command?
Everytime I type upgrade it says
CCBR007 must use card 0 port 0 fro the UPGRADE command
Thanks!
I just got a SLR5 tape drive to backup my Meridian Mail System and Messages but after wiring it all up - SCSI cable to top SCSI connector of the SLR5 and the terminator in the bottom slot with an ID of 2, when I insert the MerMail card the SLR5 spins for a few seconds and then stops, then after...