I changed the PRT1 ADAN to A TTY1 ADAN and put in PRIO 1 just as you have it, the strange thing is I had to change the Baud from 9600 8 1 N to 9600 7 N 1. I had to do that with the CTY as well.
Thanks again.
Thanks to 1norteltech who gave me the information I needed to get this to work.
By the way I am not a Nortel vendor, but we do work on them because end users can't find anyone to work on the old stuff.
We tried to get away from it but they keep finding us and we can't turn them down.
Thanks for the print out.
I will go try that set up tomorrow, but if I remember correctly, if I make the port a TTY it will not let me put the device number in PRIO in LD 23.
Thanks GreenB246,
What if I am using a qsdi card not an msdl?
And what if I'm using a PC with either procomm or hyper terminal instead of a printer?
I don't think I am getting the option to change the prams on the port.
I can probably set my laptop up again as Wyse 50 emulation 9600 8 1 none and set the stio in ld 23 to 1. Then I can change the prt 1 port back to tty 1 user acd and it will display the ongoing status report every 60 seconds. I can't have both reports trying to use the same port. It's either one...
I HAD MY LAPTOP SET UP IN PROCOMM AT 9600 8-1-NONE VT 100.
I AM NOT GETTING ANY REPORTS.
SHOULD I BE USING HYPER TERMINAL INSTEAD? IF SO WHAT ARE THE SETTINGS TO USE? WHAT EMULATION?
I AM GETTING NOTHING TO THE LAPTOP.
I HAVE TRIED NULL MODEM ADAPTER, NULL MODEM CABLES.
O.K. Guys,
I have tried the above.
Here is what I have programmed.
LD 23:
TYPE ACD
CUST 0
ACDN 2410
MWC NO
DSAC NO
MAXP 10
SDNB NO
BSCW NO
ISAP NO
AACQ NO
RGAI NO
ACAA NO
FRRT 4
FRT 16
SRRT 5
SRT 60
NRRT
FROA NO
NCFW 2400
FNCF NO
RTQT 0
SPCP NO
OBTN NO
RAO NO
CWTH 1
NCWL NO
BYTH 0
OVTH 2047...
Hi,
The SCB data block will not let me put 1 ( which is my tty port for acd) it tell me the logical device is not valid, or some such. I think the err code is SCH0730.
Any other ideas?
The SCB is as follows:
REQ: PRT
TYPE: SCB
CUST: 0
CPRD: 01 01 12 31
SHR: 7
EHR: 18
DOW: 2 3 4 5 6
RFRQ: 3
SFRQ: 2
ROPT: 1 2 3 4
PRIO:
PAGE: NO
AID: NO
-IDLB
-IDUB
-LOG
SRPT: NO
TOT4: YES
THE ACD DATA BLOCK I WILL NEED TO GET.
IF I CHANGE THE AID TO YES WILL IT AFFECT THE WAY THE...
Thanks for all your help.
I finally got the port to print to my lap top using procomm. The thing is I am only getting the ongoing status report, not the 4 reports I set up in LD 23.
Any ideas?
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.