The BFT was replaced years ago when the recal came out for the bad caps. If it still had leaky caps it would have exploded by now :)
Im sure forcing the firmware reload would be the next step and probably fix the issue, but can't find anyone that knows how to do that. Even the tech today said...
Thanks for the reply, already tried reseating, moving PEC cards, cleanig, blowing, praying.
The MSC Core load fails, the Universal profile hangs at step 1.2 and I have no dialtone on the digital sets. MSC is definitely the issue. Im able to get into the VNC session and see NT boots ups fine, so...
Tried that, then it errored out saying "Error establishing DChannel with MSC". Now its stuck in a musical tones reboot cycle and LED 1,9 and 10 are blinking Red in seried (1-9-10, 1-9,10, etc)
...reinstall either the original or new imaged HDD the system wont fully boot. I can login to Element Manager and VNC into the WinNT box fine.
The error Im seeing is:
VoiceMSCService
!* StartD1Channels: no messages from KSU during 10 secs, exiting
Anyone know what this means???
This is a...
Thanks for the tip, i've seen some FAQs on this and the refer to using the nortel BITs or some command line switces for Ghost.
If i image this, i suspect I need to pull out the drive and put it into another machine with both the new target drive right? (3 HDDs in total)
Does the new drive...
Hi,
We have an older BCM200 running 3.6. Upgrading at this time isn't feasible.
I'm looking to purchase a new/refurb 3.6 HDD and keep it on the shelf in the event the current one fails.
I've reviewed the FAQ on replacing a drive and it looks pretty straightforward, I assume the last step...
Thanks telcodog. Ironically we bought the system in 2003 from a company that was absorbed by Allstream years later. We dumped them long before the acquistion.
I really dont want to buy a BCM50, I was only price comparing. If 6k is an accurate number then I'll just replace the whole thing with a...
So I just got a quote on a 200-->450 upgrade.
$6k CAD!!!
Apparently we need to upgrade to 4.0 before you can upgrade the HW and goto Rls 6.0
We only have a GATM8, 4x16 combo card, some ATAs and about 12 ip phones (about 20 extensions in total). I can't beleive it's this expensive when i see...
OK thanks for the info, I was initially looking at the 50 becasue at first glance it appears to be about $2500 price difference, but to be fair I didn't get a price for an upgrade,just new systems.
Im going to test the i2050 phone under "XP Mode" to see if they work, and if so then use that for...
Hi telcodog, yes this is what I've been told, that I need a H/W upgrade.
My question is 2 fold:
1. Is there no other option then a Hardware upgrade to support Win7? (i.e. perhaps some version of 4.x) and if not then:
2. Can I goto a 50 instead of a 450 a retain my keycodes?
Thanks
Just to confirm, are you saying there is no software O/S version I can install on the BCM200 to allow me to use UM or Softphones on Win7?
If this is true, then next question is do you know if my keycodes can be converted from a 200 to a 50? (I think they said I could go from 200 to 450, but the...
Hi,
We have a BCM 200 running 3.6
We are starting to rollout Windows7 and one of the Nortel/Avaya partners we spoke with said we cannot upgrade the 200 to a version whcih supports Windows7 for UM and IP Phones. Apparetnly we need to goto Version 6, but it's not available for the 200. Only...
these settings will do that. The DENY overrides any grants. So by setting everyone to DENY delete, then even the creative owner can't delete his own stuff.
However, you need to be careful that someone doesn't try to create a file within the folder then rename it in the same directory. ie. Right...
Set share permissions to "everyone" read and write
Set file permissions to "Creative Owner" - Modify
"Everyone" - Read.
"Everyone" - Deny Delete
This will allow users to read existing docs, and publish new docs, and change their own docss, but no-one can delete.
Are you talking about terminal services (Remote Desktop)? That's where the 2 user/admin limit is applied.
If you need more then you need to change your terminal services to application mode and get as many users as you have licenses.
Did you run your own name servers or did you use a hosting company?
If you had a hosting company, then verify they actaully deleted your zones and not just make then inactive.
I had the same issue when we "in-sourced" our DNS. Clients that used the same provider couldn't e-mail us because the...
Hi,
When I print a single digit barcode it will not scan, when more then 1 digit it will.
Tried this on a Zebra 105, Zebra 140 and LP2844Z
ZPLII Language
Here is the ZPL code:
^BY1,3.0,76^FO105,112^B3N,N,,N,N^FDY^FS
If I change this to:
^BY1,3.0,76^FO105,112^B3N,N,,N,N^FDY ^FS
This it will...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.