Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Avstral

    IP Phone Phone Book

    megglesfield, You may fing all the instructions in ALEX under INSTALLATION INSTRUCTIONS for DBC 425. In short (copy/paste) 1.The Phone Contacts are stored on an FTP server located on the same server as used for software server. The stored file will be loaded from the FTP server when the...
  2. Avstral

    BC9 external forwarding...?

    That was a tromboning patch in BC9: /* ASSEMBLY SOLUTION : */ PCASI:UNIT=RMPS5,CI=C67990A,REV=1-R9A,IA=1DA6,RA=1DC4; END; !A...
  3. Avstral

    BC 11 - BC 12

    taurus2711, Upgrade procedure above is correct. But forget about BC12. Upgrade directly to "MX-ONE Telephony System – Telephony Switch". This is new name of MD110. You can consider it as MD110 BC13. BC12 will be in passive sustaining in 5-6 month and SP11 will be the last update. If you...
  4. Avstral

    IDLE BUSY AT IP TRUNKS

    Daddy, Looks like there is nothing about "idle/busy" in SP10 slogan. hdemir, In SP7 we had massive problems with "idle/busy" on ISDN (AU application). Getting better after upgrade to SP9. In any case, you know first rule - upgrade to latest SP - SP10. Yes, I know this will be pain in your...
  5. Avstral

    Wow! PCRegen still exists!

    Hi Tom, Thanks for share this! To add a bit of history. Year 1976. In Ellemetel (company formed by Televerket&Ericsson), the sides could not rich an agreement about size of the system - is it to be smaller or larger :) And while specs changed few times, it was born an idea that satisfied...
  6. Avstral

    silent intrusion on BC10

    Check FAQ page. Correction for BC10 is there for the last 4 years... Regards
  7. Avstral

    line lock sacops procedure

    nccoi, You don't really need a PROGRAM here. Hex value below BPOS in the table is your multno for respective equ. Regards ________________________________________________________________________________________ BPOS 0-00 BPOS 0-40...
  8. Avstral

    TLU20

    The answer is YES, you can. No limitation for ROF 131 954/2 ROF 131 954/3 ROF 131 954/4 with any R-state. Regards
  9. Avstral

    tromboning

    pawshman, As it was already noted in the above-mentioned link, for BC12 you DON'T NEED ANY TROMBONEENG patch!!!! Just use ASPAC 118 - "Loop back avoidance check selection" Regards
  10. Avstral

    Erase of NIU number

    Dutch, Reset NIU manually and try again. I did this myself and insist- this works. Regards
  11. Avstral

    Erase of NIU number

    Tested and works: R13->R10 R16->R12 R12->R10 R13->R10 R14->R13 ALL OK Not OK: R16->R10 R14->R10 R14->R12 Regards
  12. Avstral

    BC7 and HDUs

    There were no problems with HDU2&HDU3 in BC6&7. But in was not possible to use more than 255 Mbytes on HDU 6&7. That was because IPP unit used 8 bit variable to store HDU size. To override it, IPU must be at least R15A and are to load up 2 corrections in BC7.1: S48663A U45984A If you need...
  13. Avstral

    EDLU Card for BC3

    jinjin, Put in your e-mail. Regards
  14. Avstral

    EDLU Card for BC3

    jinjin, Shop around for second hand card. I know at least one company in my country able to deliver QDLU board. Regards
  15. Avstral

    Sam 3.7 Adv...

    For sure, there is. Latest is SAM 3.7 SP3 updated on 2004-12-17 (Updated files for PC-Regen) Too big to sent via e-mail. About 32 meg. Regards
  16. Avstral

    Replace with ipu

    mdfan, Very often, following STANDARD procedure means - you can't do a job. My poit is: if you afraid to step aside of standard, you are BAD engineer. As RFBOI noted earler, theory and practice are not the same. Standard procedures, standard live, odinary person, estimated standard salary...
  17. Avstral

    CAS ext. dialing congestion- need Help

    Well, I still do not understand, what "~9000 records" are? Internal number, external number or what? But if you need to find bottleneck in you system, start proper trafic recording first. Read TR description in ALEX - this is VERY poweful tool. Start recording on CAS extencions, in all the...
  18. Avstral

    Replace with ipu

    RFBOI, Could you, please, read original question? The swapping procedure assumed that NIU and IPU BOTH has correct LIC in there. Your's comments N 2&3 and mdfan's response can be described with one word only. BULLSHIT. Nothing personal. Explanations: "The NIU will have had the EIC number...
  19. Avstral

    CAS ext. dialing congestion- need Help

    Buddy, I really tryed to understand your problem .... Possibly I'm too stupid :(( "Callorg" - you have an outgoing call in line state. "Register" state is the next state of the call. No problems here. Yes, you have rather high load. Rather close to max possible in multy-LIM system. You...
  20. Avstral

    Reouting in BC.9

    Well, as soon as we still have RMP unit, for BC11 (SP13) you can use this: PCASI:UNIT=RMP,CI=BC11TRO,REV=1-R18A,IA=2D850,RA=2D85C; END; !A...

Part and Inventory Search

Back
Top