Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. SXWizard

    Can't put baud rate for my system port Mivb 10.0

    Found this in he MiVB Help files: Baud Rate System-generated, protected field. Indicates the operating speed of the port. The maximum programmable baud rate is 19200. Note that although it is possible to enter new baud rates via the command line, these changes do not actually take effect in the...
  2. SXWizard

    Mitel MiVoice Business - Incoming and outgoing calls keep ringing for phones that are not online

    What happens if you call the DID extension from an internal extension?
  3. SXWizard

    Micc Messaging port out of service

    On the MiVB did you assign a COS to the message port (RAD) with the correct timers set for the recording length? if not, then the MiVB will take the RAD out of service.
  4. SXWizard

    no outgoing via sip trunk

    it is possible that your outgoing callerID (DID Servce Number) is not allowed by the carrier. Are you using a MBG in the SIP trunk connection?
  5. SXWizard

    Switched from Avaya IPO to Mibusiness solution. Call status software similar?

    In Maintenance use the State command, i.e.State Extension xxxx, etc.
  6. SXWizard

    RAD Workflow CC Bisiness

    Did you create a COS for the RADs and set the timers correctly? if not then the RAD will fail ad go out of service.
  7. SXWizard

    no outgoing via sip trunk

    What happens when attempting an outgoing call? Fast busy, etc? What appears on the screen of the pone making the call?
  8. SXWizard

    MiCollab/Teams Integration

    Look for MS Teams Solution Guide and Mitel Assistant User Guide. Also, Mitel Assistant 1.1.1 Configuration and Troubleshooting Guide and Mitel Assistant Release Notes.
  9. SXWizard

    Mitel Major Trunk Alarms

    Go to Maintenance commands and run the State command on each of those PLIDs. Look for something Out of Service etc.
  10. SXWizard

    Mitel MiVoice Solution

    Here is a list of supported hones from a MiVB release 10.1 system.
  11. SXWizard

    Mitel Major Trunk Alarms

    Login and celect trunks. Then select Analog trunks>Trunk Assignment to see if you have analog trunks. Do the same for E&M Trunks.
  12. SXWizard

    Mitel Major Trunk Alarms

    It appears that you have PRI and SIP trunks. Are there any other type of trunks connected to the controller - E&M or LS/GS?
  13. SXWizard

    Mitel Major Trunk Alarms

    can you issue the SIP LINK STATE ALL command in maintenance to see wha SIP link is down?
  14. SXWizard

    Mitel Major Trunk Alarms

    What type of trunks does your system have connected - PRI, SIP. Analog LS/GS. E&M?
  15. SXWizard

    Revolutions - Filter alerts by property

    Create a notification fr each building/property. Then add the security person(s) to that notification.
  16. SXWizard

    MItel 6930 Broadcom upgarde

    Is it possible the phone is in SIP mode, not Minet mode?
  17. SXWizard

    MiVB 8.0 locate sip extensions

    Maintenance and Diagnostics>IP Telephone Inventory>All IP Telephones will list the device type
  18. SXWizard

    2 WAN Ports - Redundancy

    When you connect with Putty use admin as the username, not root. This will bring up the admin menu. Select 2 to configure the server.
  19. SXWizard

    2 WAN Ports - Redundancy

    Using Putty login to the MSL interface as admin. From there you can configure the server NIC settings in step 2 - Configure this server.
  20. SXWizard

    MXe-III-L Controllers and MiVB 8

    The MXe III-L does require release 9.1 or higher. Fro the Help file: MiVoice Business Release 9.1 New Hardware and Tools A new controller, MXe III-L (where L stands for LAN), is added to the family of 3300 ICP controllers. The MXe III-L controller is a functional replacement for the MXe III...

Part and Inventory Search

Back
Top