There are a few other reason for maintaining TDM phones. One being that modems if needed do not work so well under IP. Add to that (especially in a hospital), Redundancy. Right now if the network goes down, you have phones. If the phone system goes down you have network. If you switch out...
If your clock controller is not working, the system can not sync with the far end. That will result severe Slips and Loss of Framing errors. After those errors build up, the loop will drop. Sometimes it will come back, sometimes it will not and simply lock up on you. That is when you have to...
Yes, you use IDC table in load 49 to point to an existing programmed extension in your system. There is no need to do any further programming for DID's. The system takes the received digits from the PRI and processes them. If you have an existing extension that matches the incoming digits...
I understand that NPR0750 means that it is busy with another request, but that is what I get every time I try an IDC. However, IDU works every time. So, I know that it is not actually busy with another request. There has to be something preventing it from getting ID of cards as opposed to...
Here is the problem: We have a CS1000 at a local hospital connected to all their clinics around the city through IP to Survivable Media Gateways. I can get status of cards. I can IDU for ports. But I can not use IDC to check line cards. This is of course very useful to make sure Analog cards...
All those things checked with no problems noted. As for the MC32 cards no we have 2 other shelves with one MC32 card, and one other shelf with 2 MC32 cards.
all current patches installed. No audit messages. Here is the most current error message with what is just before it:
% DIAG004 Diagnostic - p1=0x1 - p2=0x0 - p3=0x0
% p4=0x0 - p5=0x0 - p6=0xa24f225
%
% DIAG004 Diagnostic - p1=0x16 - p2=0x0 - p3=0x0
% p4=0x0 - p5=0x0 -...
I don't know about peak hours. We haven't been doing any traffic studies at the times. But I would guess not, as there doesn't seem to be a specific time of day when they come in.
No, I have only seen it for loop 20 in this one switch.
Knowledge: Your number one stupidity condom...
Just 20-0 and within that shelf are 2 MC-32 cards(NTVQ01BA), 1 Universal Trunk card (NT8D14CA), and the rest of the shelf is populated with digital line cards (NT8D02GA).
Sorry I didn't get back to you guys sooner. I've been waiting until this past weekend for the engineer to load patches and INI the system for the changes to take affect. version info below:
We have 4 switches all the same version, but this is the only one that we are getting that error on. We...
I have been getting XMI005 error about every week or two. This is the most recent one:
XMI005 20 6 2 1 9:59:24 13/03/2012
I can not find much out about this error. If I look it up in the switch or in the system message book, it says it's critical.
"XMI0005 L A S T t
No message registers...
...I start out in load 32 it works fine. If I start out anywhere else it trys to go to load 80 and then of course does nothing. see below.
OVL000
>****
OVL000
>***
OVL000
>stat 56
OVL013
> 0
OVL013
> 0
OVL014
>****
OVL000
>LD 80
TRA000
MARP NOT ACTIVATED
.*
.***
.
OVL000
>LD 80
TRA000...
Ok, so far I've tried JP's script and it was not quite right...
I made the following changes and it worked like a charm.
Changed fopen 0 "tnb.wud" read to fopen 0 "tn.wud" read
added waitfor "." in this location:
transmit "^M"
waitfor "."
count += 1
endwhile
fclose 0...
SLT will lie to you about ACDNs.
see below...
TNS 8500 LEFT 5085 USED 3415
ACDN 24000 LEFT 23761 USED 239
According to that I still have 23761 available. But 240 is the max allowed on the system.
Knowledge: Your number one stupidity condom...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.