  1. ripper65

    Dect IPBS V4

    Dect Base Stations are now V4 varient. Is anyone having difficuties introducing V4 units on V3 site?
  2. ripper65

    DBM32 Module lockup

    I have a site with DBM32 module attached to 1416 phone. The module sometimes locks up, the button LED status remain the same. To clear the issue both the handset and module are unplugged then re-plugged. This has also occurred on another site, handset and module have been replaced. The units are...
  3. ripper65

    1140E with USB headset

    Check if USB headset is supported on the 1100 series with BCM, check the firmware the handset should have to support handset. It may be supported on a CS1000 system but then the handset would download different firmware to support USB headset this may not be the case for BCM.
  4. ripper65

    BCM to BCM 400 4.0 IP over WAN

    Guys Sorry to come in late but why don't you have destination codes for each site. Users at each site will dial the site number then the extension. The site number can be passed to the other site were it can be entered in the received digits of the Target line and then associated to a User...
  5. ripper65

    video intercom

    This sounds like a third party product which may intergrate via a Alog Extension or Alog trunk to the BCM. Check the spec of the intercom system.
  6. ripper65

    After Hours Answering Service

    Feature 84 is line redirect from the handset instructions below Setup of the Redirection destination: Redirection can be setup on a permanent basis by setting the relevant Target Line’s ‘Redirect To’ number to the number to forward the call to. It must include the access code ‘9’ (where...
  7. ripper65

    Sip Trunk Provider for BCM50 version 3

    Thank you for your reply, I have received news from another source that SIP may be certified in the second half of this year with a major UK provider. Thanks once again
  8. ripper65

    Sip Trunk Provider for BCM50 version 3

    Is there a Sip provider that will work and has been tested on BCM50 version 3 to provide SIP Trunks in the UK I understand Nortel need to certify SIP Providers FOR interoperability but in UK this does not seem to be the case.
  9. ripper65

    Dect crackle on BCM50B V2 WITH Alog Line

    I have a system that is using a Dect DMC unit with 12 handsets. The system only has 1 Alog line as it is a residenal house. Issue we have is that when external call is made with Dect handset there is a annoying crackle in background, calls made with test digital handset are fine and Alog line is...
  10. ripper65

    Reporting For Call Center Password

    Are you able to be specific with the file name and location, I would want to be 100% with this proceedure. thankyou for your support
  11. ripper65

    Reporting For Call Center Password

    The installation is a few months old so we do not want data lost unless it is a last resort.
  12. ripper65

    Reporting For Call Center Password

    Does anyone know a proceedure to default the password for Reporting for Call Center login. The Default is user "admin" and password "0000" but this has been changed and nobody knows any alternative password. Does anyone know how to default the Administrators password
  13. ripper65

    Video Conf with BRI ST Module

    Did you get this working? What was your setup? Did you get incomming calls to answer and combine the channels?
  14. ripper65

    Least Cost Routing With Extension Billing

    Does anyone know? I dont think the BCM has this option can anyone confirm.
  15. ripper65

    Least Cost Routing With Extension Billing

    Can the BCM send out the Extension number of the user when a call is made as digits going to line? IE When a user dials a number the system prefix's the digits with the alternative carrier access number then the number of the extension that dialed. Some carriers us this as they are able to...
  16. ripper65

    Extension Billing

    Senk1s Thankyou for your reply. I understand now that the BCM cannot sent the extension number after the carrier code. There are some special codes that can go in the number field of the route for pause and wait for dial tone but nothing that will send extension number. I will enquire with...
  17. ripper65

    Extension Billing

    The carrier code is the code to reach the Alternative carrier ie 1601 then the extension number follows then the actual number dialed. Some alternative carriers in the UK can send billing back to the end user with the extensions that made the calls this saves the site from having their own call...
  18. ripper65

    Extension Billing

    Is the BCM able to send the extension number with the carrier code for the purpose of extension billing from the alternative carrier. If the Answer is yes I would be grateful for a brief setup explaination.
  19. ripper65

    DS 30 dead ports

    56xx series are IP Terminals not sure why you are connecting these to a DS module, 54XX is what you need. 56XX only on LAN ports!
  20. ripper65

    Interquartz and IP Office recall issues

    I have tested this using 2.1.44 with a pots 30 Module to have recall issue, pots 16 and pots on main unit were fine. A maintenance bin file for the pots 30 was used to resolve. Please esculate through your channels to get this fix.