I'm looking for information on how to loopback a TAPI interface between a PC and a Siemens Optiset phone. I need to remove the phone from service, but the directory application on the PC will not start unless it sees the phone. I tried using a standard RS 232 loopback on the serial port of the...
OBTSYSTEMS: Sorry I was unclear. This system is in the USA and I can perform a trace under Call Monitoring, but I do not see where the ISDN Message Decoder is.
DONB01: we are using 4 digit extensions. I don't see any GDTR rule anywhere in the configuration. I don't know how to get into Expert...
Is there any way to list the individual speed dial numbers that users store from their phones in the Hipath 4000 V2? I have used the API Export function for extensions and line appearances, but do not see any way to list individual speed dial numbers.
Thank you ! I have a version 4.0 kv045 which also gives me an error when I try to use it, but from your post, I just need the 4.0 kv053. I will look around and see if I have a disk somewhere. We purchased so many of the Hicom 300's, we must have the right software I need at one of the sites...
Not sure which software release I have on the switch. When I connect via LC-WIN, it shows version 2.10 kv053 on the switch. When I log in to rsca, it shows Hicom 300H V1.0US SMR 01 SMP 07 UNIXWARE 7.1.0. Is there an AMO that shows the software release ?
I am looking for a copy of the LC WIN 2.10 kv053 software.
Since the original has disappeared from the site, I cannot make any software changes unless I pay for an upgrade to the Hicom. Any help would be appreciated.
I need to pull all the secondary ( or other ) lines for each phone. I can't seem to find the right field. I am using PORT for my table in the API Export table. Should I be looking in another table ?
You are correct, we do not have a closed number network here.
I checked the node numbers in TDCSU and RICHT/LDAT, but I am confused as to where they should not be the same anywhere.
IE: the node numbers in TDCSU for both trunk groups are set to 1. In RICHT/LDAT, the node numbers are set to...
Thank you, that does translate over a bit. I have to delete the station in dpln and re-add it as a TIE in dpln. Then I have to add the digits in LCR Digit Pattern. I can now call the station via the tie circuit, but outside calls to the DID number are not going through. This may be some sort...
I need to route station numbers ( on a one-by-one basis )to a route that already exists in a Hipath 4000 V2. The route exists as a LRTE and connects to a Cisco gateway. I cannot figute out how to re-route the station numbers. I can't route the whole range of numbers ( 3xxx) because we are...
I see it now, thank you.
I can pull the extension rabges I need, but I can't seem to extract the display names. I am using ( ? and * ) for wildcards, but still no names. Am I missing something?
Is there a way to export the Stations in a Siemens Hipath 4000 V2 to a file or database? I am trying to get a list of extensions that are programmed in my system.
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.