Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. lazycalm

    Chronic Static

    Loop 7 has no clock controller on it, I'd have to shut down the system, and I have no idea how to program that anyway. Are you suspecting that this is caused by the primary clock?
  2. lazycalm

    Chronic Static

    Yes, the clock source is the trouble PRI, loop 2. .ssck 0 ENBL CLOCK ACTIVE CLOCK CONTROLLER - LOCKED TO SLOT 2 PREF - 2 SREF - FREE RUN AUTO SWREF CLK - ENBL NO ERROR
  3. lazycalm

    Chronic Static

    This is an hour after I brought it back up. It didn't seem to register the fact that I took the circuit down. I took loop 7 down at the same time (I was swapping T-1 cables) and it registered the loss of service (see further below). I didn't reset any counters. Loop 2 is the trouble PRI and also...
  4. lazycalm

    Chronic Static

    This problem may well be the cause of my upcoming nervous breakdown.... I have an Option 11 with one expansion cabinet, one PRI and one P2P tie line (T-1). Incoming callers on the PRI hear static. Users on the Option 11 cannot hear any static - it's one-way. There is no internal static and...
  5. lazycalm

    Clocking issues

    Tried trck pck, but it just returned to the prompt, no response. .trck pck .ssck 0 ENBL CLOCK ACTIVE CLOCK CONTROLLER - DTI061 PREF - 30 SREF - FREE RUN AUTO SWREF CLK - ENBL NO ERROR . DTA015 30
  6. lazycalm

    Clocking issues

    I will say though, that I've had a terminal session up for awhile and those are the only errors. It's been occurring for well over a month now, so anything that might have happened would no longer be in history anyway.
  7. lazycalm

    Clocking issues

    Checked clock status (above) and cables look fine. I tried to print the history, but the file was empty for some reason.
  8. lazycalm

    Clocking issues

    Option 61, running 25.40. I'm getting regular (every minute or so) DTA015 errors on my loop that is set to be the clock source. Every few minutes I'm getting DTC007 errors as well. I sent to telco first to test, but they reported no trouble found. The clocks look ok (below), but I'm not sure...
  9. lazycalm

    Netgear and D-Link WLANs

    In the process of setting up a controller based WLAN, but I can't seem to find a lot of feedback on Netgear vs. D-Link. Both products look attractive for a variety of reasons, but I can't decide between the two. Does anyone have experience with either product?
  10. lazycalm

    Trunk to Trunk Problem

    GHTROUT - of course, that makes perfect sense and it worked to change the NCOS in LD 14. I did not try the other method. Thanks.
  11. lazycalm

    Trunk to Trunk Problem

    I have a TIE line which goes from Site "A" to Site "B". Site "B" has a PRI which I would like to access from site "A". Currently, I can dial across the TIE line and out the PRI, but only on local calls. I figure there is a problem in the route programming on the Site "B" side of the TIE line...
  12. lazycalm

    ANI Format

    Just to clarify, I'm talking about the display on the M3904 itself, not the external display. As to the ANI_DATA, it seems to only take digits - no dashes.
  13. lazycalm

    ANI Format

    Does anyone know how to change displayed ANI format from 123456790 to either (123)456-7890 or 123-456-7890? I believe I've seen this elsewhere, but can't remember. Rls is 25.40.
  14. lazycalm

    Aruba, Cisco, Nortel??

    I'm installing a WLAN, initially for the purpose of using IP phones in a hospital setting, but later on I will use it for public access, laptops, etc. Vendor has given me three quotes for AP's: One from Cisco, one from Aruba and one from Nortel. Nortel is looking to be the cheapest route, but...
  15. lazycalm

    Message Waiting Lamp across PRI

    OK - Yes I see in the book that PNI=0 will disable NMS. I changed PNI=1 at both sites (all circuits). It still will not light the lamps.
  16. lazycalm

    ANI displays an 'H'

    Good to know since we're going to 5.5 very soon. Thanks.
  17. lazycalm

    Message Waiting Lamp across PRI

    Doesn't appear to be. Would I just program RACP QMWI on the route? Here's the existing programming: TYPE RDB CUST 00 DMOD ROUT 20 DES TIE TO MEM TKTP TIE NPID_TBL_NUM 0 ESN NO CNVT NO SAT NO RCLS EXT DTRK YES BRIP NO DGTP PRI ISDN YES MODE PRA IFC SL1 PNI 00000 NCNA YES...
  18. lazycalm

    Message Waiting Lamp across PRI

    Checked the packages. Both switches have NMS - 175, PNI is set to zero at both ends, still no MWL. There's another problem: The voicemail recognizes my number, so I know that part is working, but if I call forward my phone, the opt. 11 sends the 61 the digits of the incoming caller - which...
  19. lazycalm

    ANI displays an 'H'

    Yes, you're right - VM works fine. However, the H still annoys me. . .
  20. lazycalm

    ANI displays an 'H'

    Next time you get Nortel India, ask to speak directly to Vishnu or Arjuna - they have ALL the answers. My main reason for wanting this is that I want to set up a remote site to use the VM at the main location - it's not currently working, and I suspect that it doesn't like the H in front of the...

Part and Inventory Search

Back
Top