Loop 7 has no clock controller on it, I'd have to shut down the system, and I have no idea how to program that anyway. Are you suspecting that this is caused by the primary clock?
Yes, the clock source is the trouble PRI, loop 2.
.ssck 0
ENBL
CLOCK ACTIVE
CLOCK CONTROLLER - LOCKED TO SLOT 2
PREF - 2
SREF - FREE RUN
AUTO SWREF CLK - ENBL
NO ERROR
This is an hour after I brought it back up. It didn't seem to register the fact that I took the circuit down. I took loop 7 down at the same time (I was swapping T-1 cables) and it registered the loss of service (see further below). I didn't reset any counters. Loop 2 is the trouble PRI and also...
This problem may well be the cause of my upcoming nervous breakdown....
I have an Option 11 with one expansion cabinet, one PRI and one P2P tie line (T-1). Incoming callers on the PRI hear static. Users on the Option 11 cannot hear any static - it's one-way. There is no internal static and...
Tried trck pck, but it just returned to the prompt, no response.
.trck pck
.ssck 0
ENBL
CLOCK ACTIVE
CLOCK CONTROLLER - DTI061
PREF - 30
SREF - FREE RUN
AUTO SWREF CLK - ENBL
NO ERROR
.
DTA015 30
I will say though, that I've had a terminal session up for awhile and those are the only errors. It's been occurring for well over a month now, so anything that might have happened would no longer be in history anyway.
Option 61, running 25.40. I'm getting regular (every minute or so) DTA015 errors on my loop that is set to be the clock source. Every few minutes I'm getting DTC007 errors as well. I sent to telco first to test, but they reported no trouble found. The clocks look ok (below), but I'm not sure...
In the process of setting up a controller based WLAN, but I can't seem to find a lot of feedback on Netgear vs. D-Link. Both products look attractive for a variety of reasons, but I can't decide between the two. Does anyone have experience with either product?
I have a TIE line which goes from Site "A" to Site "B". Site "B" has a PRI which I would like to access from site "A". Currently, I can dial across the TIE line and out the PRI, but only on local calls. I figure there is a problem in the route programming on the Site "B" side of the TIE line...
Just to clarify, I'm talking about the display on the M3904 itself, not the external display. As to the ANI_DATA, it seems to only take digits - no dashes.
Does anyone know how to change displayed ANI format from 123456790 to either (123)456-7890 or 123-456-7890? I believe I've seen this elsewhere, but can't remember. Rls is 25.40.
I'm installing a WLAN, initially for the purpose of using IP phones in a hospital setting, but later on I will use it for public access, laptops, etc.
Vendor has given me three quotes for AP's: One from Cisco, one from Aruba and one from Nortel. Nortel is looking to be the cheapest route, but...
Doesn't appear to be. Would I just program RACP QMWI on the route? Here's the existing programming:
TYPE RDB
CUST 00
DMOD
ROUT 20
DES TIE TO MEM
TKTP TIE
NPID_TBL_NUM 0
ESN NO
CNVT NO
SAT NO
RCLS EXT
DTRK YES
BRIP NO
DGTP PRI
ISDN YES
MODE PRA
IFC SL1
PNI 00000
NCNA YES...
Checked the packages. Both switches have NMS - 175, PNI is set to zero at both ends, still no MWL.
There's another problem: The voicemail recognizes my number, so I know that part is working, but if I call forward my phone, the opt. 11 sends the 61 the digits of the incoming caller - which...
Next time you get Nortel India, ask to speak directly to Vishnu or Arjuna - they have ALL the answers.
My main reason for wanting this is that I want to set up a remote site to use the VM at the main location - it's not currently working, and I suspect that it doesn't like the H in front of the...