Okay figured it out. CUCM Admin> System> Service Parameters then pick your Server and Service is Cisco CalManager then go down to T302 Timer. Ours was set at 3000 so I changed it to 6000 to see how that works.
I’ve done a search and saw that link but I don’t see that menu in our CUCM. We are on version 8 and I’m in the CUCM Administration. Do I navigate to the CU Serviceability, CU OS Administration or stay where I’m at?
Thanks
Where in the CUCM can I change the delay when entering the phone number on the phone? It busy out if you take to long entering the number and has become very frustrating to enter the number quickly.
Thanks
I apologize; I have to hand jam it and was trying to avoid any unnecessary typing.
There are no entries in the speed call list and here is the CLS:
CLS UNR DTN FBD XFD WTA THFD FND HTD ONS
LPR XRA AGRD CWD SWD MWD RMMD SMWD LPD XHD SLKD CCSD LND TVD
CFTD SFD MRD C6D CNID CLBD AUTU
ICDD CDMD...
Oh sorry, there is a phone out on the fence and to call one of us in the building they pick up the handset and dial #32 and 5030 rings inside our building, dial #33 and 5056 rings in our building or dial #34 and 5512 rings inside our building. I assumed the phone is using SCU since I saw it in...
On a Meridian Option 61C Rls 25.47 and I’m trying to get the speed call user working again on this one phone, the phone in question:
REQ prt
TYPE tnb
TN 12 1 5 4
DATE
PAGE
DES
DES 5125
TN 12 1 5 4
TYPE 500
CDEN 4D
CUST 0
WRLS NO
DN 5735
AST NO
IAPG 0
HUNT
TGAR 1
LDN NO
NCOS 1
SGRP 0
RNPG 0
XLST...
I would like to move the secondary clock source to the commercial E1(loop 24), we are using two T1s (loop 9 & 26) at the moment; what do I need to do, is it possible to have one T1 and one E1?
CEQU
MPED 8D
TERM
REMO
TERD 010 011
REMD
TERQ
REMQ
SUPL 004 012 020 N064
N080 V096
SUPC
SUPF
XCT 000...
I have an Option 61. If I want to change the secondary clock source from loop 9 to loop 24 how would I do that?
>LD 60
.ssck 0
ENBL
CLOCK ACTIVE
CLOCK CONTROLLER – TRACK ON LOOP 26
PREF – 26
SREF – 9
AUTO SWREF CLK – ENBL
NO ERROR
.ssck 1
ENBL
STANDBY
CLOCK CONTROLLER – TRACK ON LOOP 26
PREF –...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.