Recent content by epcompx2

  1. epcompx2

    Name change on internal dialing

    Check the Personal Directory on the phone.
  2. epcompx2

    Caller name not displaying from some sets

    I notice that my 1230 IP phones will only display 17 characters or less even though MXLN is set to 27. I thought I read this limitation somewhere but cannot find the documentation to support.
  3. epcompx2

    Caller name not displaying from some sets

    Below is LD 95... Verify MXLN REQ aaa Req = NEW or CHG TYPE CPND Type = CPND (Calling Party Name Display) CUST xx Customer number associated with this function CNFG aaaa Configuration (aaaa = (ALON), REMO, or LOCL) MXLN 5-(17)-27 Maximum Length STAL (NO) YES Static Allocation of name storage -...
  4. epcompx2

    Caller name not displaying from some sets

    Verify name length in LD 95
  5. epcompx2

    Extension handset picked up, but has to press line.

    Is the phone programmed to ring on incoming calls?
  6. epcompx2

    911 broken in LCR

    8A4005>9:0002-CCC You have to clear 9 first.. Then build 90, 910-919, 92-99
  7. epcompx2

    Original MGM Grand Hotel Las Vegas, was it a Northern Switch?

    Just an FYI... The MGM Grand Hotel that the OP was asking about is now Ballys. The current MGM was built "around" the old Marina Hotel in the early 90's.
  8. epcompx2

    Original MGM Grand Hotel Las Vegas, was it a Northern Switch?

    The current MGM (not Ballys)was installed with NEC 2400 and later changed (after 2002) to Nortel. Las Vegas in general has quite a bit of NEC, at one point they claimed 50% of the large hotels downtown and on the Strip.
  9. epcompx2

    Before Norstar there was the Northern Telecom Vantage System

    State of Nevada had quite a few of these... We called them DIS AD Vantage!
  10. epcompx2

    Electra Elite 192

    Feature" + "3
  11. epcompx2

    NEC ESIB8 is not recognized after installed and programmed

    It is an epromm. If you dial "Feature" + 3 the display will show you if the CPU is 48P or 192P. If it shows 48P the CPU will require the PKU (epromm) o increase the port capacity from 48P (32 sta x 16 co) to 192P (120 sta x 64 co).
  12. epcompx2

    NEC ESIB8 is not recognized after installed and programmed

    Do you have a PKU on the CPU, which is required for more than 32 extensions.
  13. epcompx2

    DT330 Problems

    Check MENU 5 1 1 and verify that headset ring is disabled
  14. epcompx2

    UM8000 how to reset login password?

    Is anyone else a System Manager (you?), you would log in with 9XXX + that mailboxes password. We usually build 2 mailboxes with system manager status so we can get in when someone does this. Good Luck