Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations John Tel on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by broncos1112

  1. broncos1112

    Mitel 3300 Paging "cut-outs"

    Yes, I am using the paging port out of back of 3300 server. And I have had the audio cut out using a butt set plugged directly in to back of server. Again though, inconsistent.
  2. broncos1112

    Mitel 3300 Paging "cut-outs"

    Has anyone seen this problem on a Mitel 3300 IP system? Whenever customer pages over speakers the audio drops for approximately 5 seconds. The call does not drop, if you keep talking the voice will be heard over speakers again. This is an intermittent problem. I have replaced the analog adaptor...
  3. broncos1112

    Adding M2250 Att. Console to MG Branch office

    Trying to add an attendant console to CS100 Media Gateway Branch office. Cannot get it to work.Has proper SLT. Documentation does not mention M2250 as being compatible. Has anyone installed M2250 on a branch office? Any ideas? Thanks
  4. broncos1112

    Cannot transfer call from cs1000 IP Set to Bcm phone via IP trunks.

    Adjusted timers. Also took inc. DID calls out of the equation. Could not transfer an internal call from BCM phone to IP phone to BCM phone. Any other ideas anyone?
  5. broncos1112

    Cannot transfer call from cs1000 IP Set to Bcm phone via IP trunks.

    Here is scenario. Incoming call to Ext #1511 via PRI Did trunks. X1511 is an IPset (1230 type). Try to xfer call to other ext #1504 which is a 7208 type phone off of BCM 200. IP trunking involved. CS1000 Pbx is the main site with media gateways, Opt 11, and bcm 200 and bcm 400 tied together...
  6. broncos1112

    Name display and ringing issue on 2nd DN

    Thanks guys for the info. That worked.
  7. broncos1112

    Name display and ringing issue on 2nd DN

    Here's the scenario: Recently upgraded school system. cs100E to 5.0. Off site elem schools converted to cs1000MG. Loops 4-0 and most recent Loop 4-1. The recept phone and admin phones are 2616 type. 2nd incoming call (while on key 0 on another call ) beeps once, doesn't continue to ring, while...
  8. broncos1112

    Signalling Server/CP-PM will not fully link up

    Thanks for the input from everyone. Customer is OK with the ability to access pbx via Virtual Term. He doesn't need H.323 license for now.
  9. broncos1112

    Procomm Vs OTM?

    I completely agree with John Pooles assessment of OTM/TM. Procomm is much easier to deal with.
  10. broncos1112

    ARS (Auto Set Relocation) POLL

    Try to avoid it if at all possible.
  11. broncos1112

    Signalling Server/CP-PM will not fully link up

    Yes, it is added in Element Mgr. I think it may be a problem with no H.323 licenses in switch. Thanks
  12. broncos1112

    Signalling Server/CP-PM will not fully link up

    Yes I'm having trouble establishing that link. How do I do that? Thx
  13. broncos1112

    Signalling Server/CP-PM will not fully link up

    New install CP-PM Sig Server. Green LED keeps blinking. I have re-installed software (Succession 5.0),swapped out, elan patch cable, and of course rebooted several times. I can ping IP address via Ld 117, and can also get into Element Mgr via Tlan. I can also get into switch via virtual term. Am...
  14. broncos1112

    Dalayed message notification/CP 4.0 703 standalone application

    Thanks 56BelAir. That is what I was planning to do also.
  15. broncos1112

    Dalayed message notification/CP 4.0 703 standalone application

    Issue with call pilot 4.0. Large city gov't. customer. Getting complaints of delayed message notification. Intermittently, no pattern established. Not even the same ext #s. Is there something in settings to change? Or a patch for this? Any ideas anyone? thanks Mark Lee/Copperstate Comm.

Part and Inventory Search