  1. vulcanccit

    Audix answers but you hear nothing

    We have a new issue... when they pulled the supply and put the new one in, upon boot, it displays Sanity Error. The thought was the Cmos battery was dead and it lost its settings. New battery is in... Sanity Errors even on the old power supply. What can we check to see what got...
  2. vulcanccit

    Audix answers but you hear nothing

    Joe and gang, the director of engineering for that radio station is a top notch engineer/designer and he found that the power supply he replaced it with does not include the -5 volts that the DSP section needs. So, he has the correct supply coming on Friday. He found that these newer ATX...
  3. vulcanccit

    Audix answers but you hear nothing

    understood, thank you Joe!
  4. vulcanccit

    Audix answers but you hear nothing

    ok ill advise them, they are now opening up the box and looking around
  5. vulcanccit

    Audix answers but you hear nothing

    Another question about the DSP cards... are they separate from the 2 cards that have the RJ11 connectors on them?
  6. vulcanccit

    Audix answers but you hear nothing

    Thank you Joe!
  7. vulcanccit

    Audix answers but you hear nothing

    thank you! do you folks know if this card is somewhat standard? is it an Ebay thing? or can it be purchased somewhere?
  8. vulcanccit

    Audix answers but you hear nothing

    yuck! I think the mother board is ok as the rest of the audix system seems to work... you can make users, change passwords, etc. I work for IheartMedia and we have a lot of radio stations that used to use Avaya, so we are hoping one of our other stations have some cards we can use. Waiting...
  9. vulcanccit

    Audix answers but you hear nothing

    Yes all vm port extensions ring, then answer, and silence.
  10. vulcanccit

    Audix answers but you hear nothing

    I will have them check... I would think it would be the same as when I traced a station, I saw it dialed one of the stations... traced it again, it dialed a different station, same no audio. I cant check directly as I am doing this remote and am not in that market. DSP board is a good idea to...
  11. vulcanccit

    Audix answers but you hear nothing

    One of our markets had a power supply failure in it's Intuity Audix system. they replaced the supply. If you dial audix, it answers but you do not hear the typical "welcome to audix" Same if you call an extension, it covers to h99, hunt group is sending it to one of the 12 analog stations set...
  12. vulcanccit

    Audix - what am I missing? Audix wants extension instead of going to the mailbox.

    I got this solved... luckily I have access to the original programmer from our BP who set a lot of this up. these 2 numbers were not in the Private Numbering table. I didn't know that table even existed lol. Luckily he said he forgets that table often... however in my case, I never knew it...
  13. vulcanccit

    Audix - what am I missing? Audix wants extension instead of going to the mailbox.

    Extension is 82468 VM box is 82468 Coverage path is 5 (5 rings) After 5 rings it goes to H99 which dials the audix extension but instead of it going to the users mailbox (and playing the greeting) it is asking fo the extension and # sign. trace of this station looks no different that traces...
  14. vulcanccit

    Session Manager 6.3 Web interface issue

    So this ended up being expired certs, both on our local system manager and a disaster recovery ess at our data center. I didn't know it but the GRreplication does indeed replicate to the ess. Also the replication was failing due to the NTP ip that our BP used on the DR ESS is not longer...
  15. vulcanccit

    Session Manager 6.3 Web interface issue

    Also I did a few reboots via SSH to no avail a day or so ago.
  16. vulcanccit

    Session Manager 6.3 Web interface issue

    I can't get to the page and I do not recall what is on the GR Page. This was all set up by our BP and about the only thing I ever used System Manager for was to goof around with Sip Users but we ended up doing H.323. Yes I have an email into our AOS lead. I will also email our BP as they will...
  17. vulcanccit

    Session Manager 6.3 Web interface issue

    Kyle, I can't seem to find ticket notes in my emails from Avaya, I think they are no longer in my inbox. I searched on Avaya's site but it is having issues lol. However, we have Avaya AOS Service Release Management and in December they advised of a Cert that had expired on SMGR. At the time I...
  18. vulcanccit

    Session Manager 6.3 Web interface issue

    it is is when I log into the System Manager from the web page. It might be certs, we had an issue with them before but I do not remember this error. I rarely am in this box as we really do not use it for much. This system is soon to be migrated into our Business Partner's ECasS cloud...
  19. vulcanccit

    Session Manager 6.3 Web interface issue

    after accepting my credentials, the web page displays "Server - Unknown Mode (GR Replication - ) and over on the right upper corder there is a Notification yellow yield sign with ! in the middle. When you click that it says Secondary Server status : Unknown I have done a reboot via SSH with...
  20. vulcanccit

    Viking E-30 Door Phone hooked in as a 2500 set type

    turns out a dip switch that should of been on by the factory was not. So now, pushing the call button during the call will hang it up. Your suggestion is good, that was going to be my next step :)