I have experienced this problem. I think Avaya are aware of customer complaints about this. If you put a finger close to where the plastic Switch hook is you can feel warm air coming from the gap around it. Some sets seem worse than others. I seem to remember there is a compenent relatively...
No this worked from the box. When on site you need to add a messaging system on ASA and use the IP address of the LX as defined in the TCIP/IP Administration / Network addressing.
When accessing remote you add a messaging system as a modem type dial up to ASA and just call the modem on the...
I have done this with ASA using VM as the log in and port 23 when on site. You can also do it remotely by just dialing into the modem and logging on as VM
Better late than never and it may help someone else. Your Lines are probably not presented to the Audix in the correct order. You need to check the extension number from the switch is terminating on the channel on th LX that is configured as that number. You can easily check this by using the...