Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. tomeguy

    VTC PRI's on a CS1000E

    Has anyone set up PRI's on the CS1000E, I have working BRI's for the old VTC equipment but the new stuff requires PRI's and I'm not really sure where start. Any help would be helpful..Thanx in advance
  2. tomeguy

    Message Waiting Problem on Analog Phones Only

    I had the same problem ...thanx for the post PR..;-)
  3. tomeguy

    bug 121 bug 128

    Aml can't send message to inactive side??? Can I INI the active one and have this go away or try ini on the inactive one ...I have a cs1000e that I've had for 2 months and it just started spitting this message out yesterday...evey 3 seconds.. Thanx Guys
  4. tomeguy

    call pilot attendant

    New call pilot..pilot. They installed it and set the attendant to the wrong number. How do I change it? also the mermail would pick up on 4 digit dialing and call pilot wants all seven. Problem is most of my phones are pointed to the 4 digit number...How do i search all the phones that are built...
  5. tomeguy

    Call pilot reset???

    thanx Matt...makes sense to me.....
  6. tomeguy

    Call pilot reset???

    Well, My vendor told me they set up the back up properly...It is the JTIC version 4.0....My training was here is how you reset a mailbox. RDC was an acronym I'm not familiar with. I have call pilot manager but with the JTIC hardening was told I couldn't do functions related to the call pilot...
  7. tomeguy

    Call pilot reset???

    OK I see now that there is a reset button on this card...I figured this was the card to reset...This is a hardened CP IF i hit the reset ??? Is it going to come up after or do OR do I need to do something to it to get it to restart??
  8. tomeguy

    Call pilot reset???

    I hate to sound dumb...but is it the rst button on the card in the cabinate labeled..(CP-PM)...I miss my MerMail..;-(
  9. tomeguy

    Call pilot reset???

    What it the proper way to reboot the call pilot card???
  10. tomeguy

    VoIP loop print and change

    What ld do I check and or change it in???
  11. tomeguy

    VoIP loop print and change

    I have authcodes in the switch all other phones need the authcodes. The ncos in the VoIP phones is 4 and the no authcode ncos is 5..I thought loop 156 might have been built with an ncos of 5 and superceded what was built on the phone..How do I prt the loop ncos and or change it????
  12. tomeguy

    VoIP loop print and change

    We just got a new CS1000e I need to chag a loop. It is not requiring authcodes for phone call I think it was built with an NCOS higher than required I just can't remember how to find or change this...Help..;-) Thanx Again..;-)
  13. tomeguy

    Call pilot reset???

    I just got a new call pilot and the ports on the front of the card don't seem to let me log into the card...It was working and we tried a different mouse and now I get nothing..Can I reset the ps2 ports or something to wake the ports up???? Thanx in advance
  14. tomeguy

    power down procedures

    The batteries died a year ago I have a new switch CS1000e sitting in the server farm...waiting for DSN to let me turn it on. Its a AC switch and the old one is DC Nobody wanted to spend 15k for 1 years worth of batteries we won't need. I knew about the cuircut breakers in the back just figured...
  15. tomeguy

    power down procedures

    I have a 61c and once a month we have a generator run up. It takes 20 seconds for the generator to auto start....1 problem my batteries are stone dead. I would like to know if there is a proper way to shut down the switch. When the power goes out the batteries cycle off and on..Its gotta be...
  16. tomeguy

    Mer Mail to call pilot tree help

    I'm converting over to call pilot and need to print the tree information...Is there a 1 stop shopping page to capture all the information I need??? Thanx in advance Tom
  17. tomeguy

    physical location via loop name???

    Acctually it works in slots 5/6 and 6/7 Thats why I was confused??? Its located in group 2 shelf 0. I've had alot of frame slips all over the switch from dead batteries and power failures burning up cards..I was timing off this loop but rewired and programed off another loop. 27 takes hits but...
  18. tomeguy

    physical location via loop name???

    Its called loop 27 there are only 2 cards in that cabinate both 720's Sorry I didn't get back to you sooner..No computer weekend..;-)
  19. tomeguy

    physical location via loop name???

    We moved around a couple cards during a swap I think 1 of the pri/720 cards is not in the right location...Is there a way to find physical location based on loop number?? I feel dumb asking this question to many people moving to fast makes terrible soup..;-)
  20. tomeguy

    frame slips on 2 of 3 three TI's Help

    I changed the card slips just as fast call in a trouble...Found out the loops are labeled right just 27 is pluged into 19 and visa versa at the smart jack....WTF Hey thanx alot for spinning your wheels with me..

Part and Inventory Search