Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. sensey

    How to change call pilot mini to call pilot 150

    SkinTech, what call pilot do you have, a 150 or a 100, and how many mail boxes does it has. Thanks
  2. sensey

    How to change call pilot mini to call pilot 150

    Hi every body...... I have a call pilot 150/Mini that works with a option 11c, my question is, how can I change the call pilot software so it can work with a Norstar system. Thanks
  3. sensey

    caller ID on combo 4X16

    Hello. I have a BCM 200 with a 4x16 combo and a 16DSM+ installed. How can a Display the caller ID before I answer the call. Because I can see the ID number but after I lift the handset. Thanks
  4. sensey

    Problem with E&M card

    Yes I did, I do the board renumbering. Thanks
  5. sensey

    Problem with E&M card

    Hello to you all. I recently change my trunk cards for ones with a caller id capability. Since then I am having some troubles with my tie lines. They seems to get freezed. And then I need to enter maintenance and do a reset and restore so they can function again Heres my hardware Inventory...
  6. sensey

    how to rename the remote access code on a Magix 1.0i V.60.0

    Hello. Does any one have made a system renumber on the remote access code on a magix v1.0i.. I am trying to do it but it wont let me. My actual remote access code in 889. I want to put it on 3.. Thanks
  7. sensey

    Restriction on night service

    Hello to you all. My question is as follows, I hace a magix with nignt ringing service, can i use this service to create a restriction sevice as well? I want to block any call after 6 p.m. Thanks
  8. sensey

    did number on outside call

    Hello to you all.. Its been a wile. My thread is this one. I have a nortel BCM 400 installed with 1 T1 cad configured as PRI trunk. I can make out side calls, but we need that the person that we are calling see My number not the main one. Example.. My did number id 4820, my main number i...
  9. sensey

    Directory not available on star talk flash 1.4

    Yes they have been initialized, and in the MB programing they have the directory set to yes
  10. sensey

    Directory not available on star talk flash 1.4

    Hi... Its been a wile since my last thread, I have a problem with a star talk flash. I enebled the directory In the initial configuration, but It tells me that the directory Its not available when I dial in to the office and de AO answers the line, I press the pound key and gives me that...
  11. sensey

    installing a 3rd PRI

    yes. Is working prefectly. But in programming it never gives me the option of PRI just Loop E&M BRI-ST and BRI-U2
  12. sensey

    installing a 3rd PRI

    Yes, is in the trunk module. in slot 1
  13. sensey

    installing a 3rd PRI

    Hello to all. I have on my system 2 PRI on the KSU. Now i need to Install a 3rd one. I new that in release 7.0 will work. I upgraded to release 7.0 but still it doesnt work. My compleate configuration is this. 1 MICS with 2 DTI working as PRI. 3 fiber station mudule 1 ASM and 1 fiber trunk...
  14. sensey

    Paging trunk card

    Hello to you all. Mi question is, can an DXUT card be used as a paging port. If so... how do i put it on the trk type? Thanks.
  15. sensey

    Need Cisco FIPS 3.6.7.f

    Can any one tell me where can I get cisco FIPS 3.6.7.f to my cisco 3002. Thanks
  16. sensey

    cisco 1751 dropping calls on fxo port

    Hello. I am havig some trouble with my cisco 1751-v, the problem is in my fxo port, on one side i had it connected to a Partner and there is no problem, an on the other side i hava a IP Office, so, when i make a call to the IP Office it goes thru, but when i make a second call to the same...
  17. sensey

    DSP error message

    Hello to You all. I am having a litle problem with my cicso 1751-v. the problem is that i can make calls within the routers, but when i am in the first call, when i make the second one, it passess but disconects me the first that i made. I make a debug on de cisco and I get this message and...
  18. sensey

    setting up a vpn over 2wire dsl modem

    Hello to you all.. I am triyng to make a vpn with a linksys vpn router over a 2 wire dsl modem. In the dsl modem i have static IP, and i make bridge connection to give the router a real ip add, so clients can connect to mi network.... Now, I already make the configuration on the linksys and on...

Part and Inventory Search

Back
Top