You have to assign the pickup group under line settings for both phones. Example pickup group #1 must be assigned to the line of both phones before the pick-up feature can work. Try that and then simulate the test again.
Guys I figured the problem out. I was using ms word to edit the .xml file, which added to much trash that the phone could not understand. I went to www.ccmstuff.net and downloaded the software xml marker from the links there. That corrected my issue with the .xml file and the files loaded with...
CCM 4.1.3--->here is my .xml file
<CiscoIPPhoneImageList>
<ImageItem Image="TFTP:Desktops/320x212x12/TN-CRC_3D_rgb-c_New.png"
URL="TFTP:Desktops/320x212x12/CRC_3D_rgb-b_New.png"/>
</CiscoIPPhoneImageList>
The png and .xml files are placed together in this directory--
C:\Program...
No, I dont see the option on the phones. I still see the default background on the user pref section in the phone. I am in the process of reviewing the .xml file. Thanks. bv25
Hi guys, does anyone know how to change the background display on 7970's? I have tried using the instructions on the cisco website but cant seem to get it to work. All phones are registered to the subscriber and the new background file is on the server. Yes, tftp is running on that server, but...
Guys need some help with changing a users access to ovly's. The user needs to be resticted to view only specific ld's.
I know it is done in ld. 17---A sample config would really help. Thanks guys.
Scr in meridian means single call ringing, usually its programmed for one set only. Scn, is the same thing but not ringing just appearing on the set. Mcr, multiple call ringing, this is programmed for an ext to appear on several sets to be answered at multiple times. The scr feature can appear...
Yes, I did exactly that today and it worked. Come to find out, the admin chg the port in his switch from 100mbps to 10mbps and the max was working on the lan. The transciever i was using was for 10mbps, they did a chg to the network this past weekend and did not let us know about it. So te max...
No i have not been able to ping max from another pc. I know the ip address for max has to be a staic ip;is there something else that i need to ask the administrator concerning the switches that max is plugged into?
thanks again.
Trying to configure MAX onto LAN, IP Address, subnet mask, and Gateway are properly configured. Having an issue with MAX pinging Gateway. Tested Transciever and cable attached to MAX. Rebooted MAX, and still can not access LAN. Can someone shed light on problem?
Thanks,
Bobby
Hi Tbzropi1,
I currently work on several 11 mini's, and all the ones that I work on have the same problem. My company has called nortel several times and we can not seem to find a solution to that problem. We have chg'd cpu's, fiber link's and the entire cabinets and we can not resovle the...
Galletti,
Thanks for your help, i finally found where to program the gateway address earlier this morning. I programmed this address using the serial port on the bcm, under system configuration, then using the quick start menu. Nortel has it named default next-hop router instead of using the...
HI GUYS,
I WAS JUST ASSIGNED A TKT DEALING WITH A BCM, HAVE NEVER DEALT WITH THEM. I HAVE A USER THAT WHATS TO REMOTELY LOG ONTO A BCM FROM NEW JERSEY DOWN TO A BCM IN ATLANTA USING THEIR INTRANET. I HAVE PROGRAMMED THE CORRECT IP ADDRESS AND SUBNET THAT WAS PROVIDED BY THE LAN ADMIN. DO I...