I got CMS V8 and suddenly it started to fail data summarizing.
I got message in error log:
1350 ERROR GENERAL error internal to process: Unable to successfully complete archiving.
And I got only interval data.
Any idea how to fix it?
I found out what was the problem.
CO lines got active function 'distinctive ringing', so for outside calls it generated 2 short rings instead of one longer. I had to change 'Ring Persistency' to shorter one.
And now it works :))
I meant 'Problem appears even when I got single icomming call'. I made 5-6 calls in a row and some of them were answered after 2 rings and some after 6-7. I was calling same line a few times in a row and I was calling diffrent lines.
Problem seems to to appear randomly, but quite often.
Power...
Thank you IPGuru, but:
Ad. 1 CLI is off
Ad. 2 I set incoming destination to VM:AutoAttendant (this is module name), but situation haven't changed.
Ad. 3 Problem appears when I got single incomming call, and I don't see calls queud nor serviced by Voicemail.
Maybe you got some other hints?
Hi,
I got IP Office 403 with IP Analog Trunk module.
There are 7 loop-start lines connected to Analog Trunk ports.
Incoming calls via these lines are directed to AutoAttendant made on VoiceMailPro.
The problem is that quite often caller has to wait something like 4-5 rings before he hears Auto...
Account code isn't a part of dialed numer. There is separate field in CDR record which contains it. Check 2nd page of
display system-parameters cdr and look for 'acct-code'. This way you will be able to locate position of this field in CDR record.
Regards,
Pieta
System was just migrated from Version 8 on Ultra to ver. 12 on SunBlade. VV Server is installed on new machine, but when I m starting it via 'setupaas' I get message like this:
08/09/04 04:23:09|AAS|20001|0|ALARM|cmsGateway|adminData.cc|319|CORBA Error Name Server Failure: *****
***** - means...
Well, what do you mean disable? As I said, when I tried to use top slot, it caused 8700 to reboot. When I used bottom slot, it was working ok. And after I read translation from MO I was still able to use top slot for backup. Btw. I checked documentation again, and it clearly states to use bottom...
Well, Last time I tried to put MOST in top PCMCIA slot of S8700 it caused machine to reboot :) For me only bottom slot was good place to put MOST PCMCIA.
Another thing is that, this eq isn't too smart, so if you have any x.25 application (Audix CL, DCS, etc.) better move them to IP or at least...
Well, I was using the ip address. But...
When I submit login screen (with proper login/password) brower tries to connect to ip which isn't assigned to Intuity. It looks like an error in login page.
Using 'vm' account isn't the solution, because access to audix application is not enough.
I m trying to access Intuity LX via WWW. It shows login screen, but when I submit it, it tries to connect to IP address, which isn't assigned to Intuity, and it fails of course. Any hints, what can be a cause?