Cisco, Avaya and Mitel are the "obvious" choices for a certain class of customer that still thinks they want or need a traditional, on premise system and a big name.
There are at least a dozen Asterisk flavors to choose from and work with to create your own on premise or cloud or hybrid...
I would bet Mitel will buy what’s left of the CPE biz. That leaves Mitel, Avaya and Cisco as the only relevant, large players in this ever shrinking, but never totally vanishing space. The end of an era it seems. Tough for us old timers to believe..
teamonesolutions.com
I posted a link to the manual above that explains in detail how to do it. It will not be formatted in a very nice way, but it is what it is..
teamonesolutions.com
The SV9100 System Maintenance Manual covers how to enable and use debug terminal. Good luck finding it on necntac.com though. I'll leave this link here for a while so you can download it if you want.
https://www.dropbox.com/s/euvrqcf9o38s4xe/SV9100-System-Maintenance-Manual.pdf?dl=0...
Another thought is that the user played with their voicemail settings and may have inadvertently done something like call screening or transfer to different number the their extension. Calling form another phone internally would reveal if the issue is in the voicemail or the phone though...
That is true. Check the subnets. I think by default they use /16 for some reason and that would explain it. Assuming you configure two different /24 networks you should be fine. You might need to save one, reset and then set the other, reset. Also know that NTAC will tell you to not use the...
And 84-26 is not where you point to. 84-26 just needs to be an extra unused address in the voice network like 10.1.10.132 in your case. Trying to attach PcPro to this post for you..
Another tip, forget about auto configuration. Think about and choose either plug and play if you don't have a...
I am trying to attach networking manual. Chapter 8 should be very helpful.
teamonesolutions.comhttp://files.engineering.com/getfile.aspx?folder=07cddc55-6e91-4926-926a-b6c7abf8417c&file=31578-2-0--SV9100-Networking-Manual.pdf
Here is the ntac note. It will come in helpful after you get networking sorted out and phones registered and then discover they still don't work:
VoIP Terminals Receive Busy Then Hang Up When Going Off Hook to Make or Answer Calls
ID# 11373 | Published 11/13/2014 10:22:21 AM | Updated...
Are you sure you have the IPLE? It is a daughterboard on the 9100. You also have to manually assign licenses for it: http://necntac.com/answer/11373
What error do you get when you try to change the IPL IP address? Are you using DHCP on the 9100 or external? I recommend using DHCP on the...
So just to bring this to a close. It all worked as it should have. These are my actual settings:
0B001>00:10.23.96.1-
0B001>01:255.255.0.0-
0B001>02:10.23.254.254-
0B101>00:10.24.96.1-
0B101>01:255.255.255.0-
0B101>02:NONE-
0B201>00:10.24.96.2-
I assigned an IP phone 10.24.96.100/24 with...
Be careful running fire alarm lines through a PBX. In my area in California, fire alarm and elevator lines are not allowed through a PBX per fire codes.
teamonesolutions.com
Hi neax, P is my father and we are business partners too. You can look us up at teamonesolutions.com
Thank you also for the reply. I think I am just going to try it and see if it works. If the site wasn't 90 minutes drive each way this would be easier. I was hoping to get something...
Thanks a lot for the reply. I will consider doing that, but was hoping to avoid a trip to a site that is pretty far for me and I would have to go out there, make changes, reset system and move cables around after doing this..
Do you know the answer to my main concern? Does it really matter if...
All, I am an old IVS guy and working on an SV8300 to enable a couple IP Phones. NTAC told me something that I could not correlate in documentation so I want to try to see if anyone knows for sure if it is correct or just a 'recommendation'.
I was told that if I already have my maintenance port...
I think you are not supposed to put any codes in yourself. They should be there automatically. I don't have time to check another system right now, but they should be left alone.
Do other mailboxes work with MW lights? You never said if this was a global or single user issue...
Did 1303 fix it? From your description I think if the dial codes work the trouble may not be 1303, but the voicemail. Someone may have changed the MWI for a mailbox or the whole (system). Is this a systemwide issue or per user?
teamonesolutions.com
I feel ya and I am not a lawyer, but I am pretty certain most of this is illegal in most countries. Especially:
3) I want to implant a small package to implement remote control of their system, it will be a Java package on a false web manager.
a) I plan to impliment a geo tracker in this...