You have to one system NS1000 and the second can be NS500. Is possible to use in mode One-Look.
Two NS500 as master and slave not be used.
Only as QSIG connection IP Gateway used mode Tie Trunk.
NEC seems to have figured out how to get payment from customers and has extended the license period including SWA and technical support, but only with PBXs with a valid SWA.
https://res.cloudinary.com/engineering-com/image/upload/v1721814733/tips/UC_OnPrem_Comms_for_SWA_Extension_vEMEA_nhhndm.pdf
To nx965
The AP500 was not developed by the NEC manufacturer, but by the Danish company RTX
So you can continue with, for example, SNOM M900.
But the systems are not officially compatible with each other. Although I managed to upload SNOM fw to AP500. and G277 handsets work.
Hello,
What is the MPR and DLC16 firmware version?
the DT5xx series requires the latest firmware in the PBX.
You must have MPR fw version: 5.0030
And also it is necessary to have upgraded fw DLC16 to version: 8.001
Yes you're right.
According to the documentation available from the manufacturer, there is no problem using VRS as an Automatic Attendant.
The AA VRS feature in the PBX is specifically designed for this use.
Using INMAIL as a priority when requesting a simple IVR tree is unnecessary in terms of...
Disabling the ability to dial external lines in the DISA/VRS/Automatic Attendant 1-digit Code system is only possible when using the following steps:
22-X Incoming Call Service – 22-11 DDI Translation table – 22-11-05 Target 2 – 401 DISA
25-02 VRS/DISA Message – on a specific Trunk, select...
Hello gentlemen,
I went through all your advice. Thank you very much for your advice.
I found in testing that your advice does not apply to my problem.
The setting of restrictions between individual groups of departments is clear to me and I understand it.
But what do I need?
Screenplay:
In the...
It is interesting,
I believe it.
I don't know how you try. You have more experience than me.
So I have to think about how to set it up as you describe and try it out as well.
Don't have a configuration backup available?
It would help me a lot.
answer for
Ozzie George
and
Coraltech
Your solution solves a situation related to the possibility of banning calls to specific offer numbers.
This means that:
For the sales department, choose 1
For the technical department, dial 2 We knew that.
The problem arises in a situation where the...
Hi all,
I dealt with a similar request.
We replaced the PABX from the original manufacturer MATRA (NeXspan), a technology that is about 30 years old.
The customer had an IVR (Automatic attendant) - 1 digit code attendant created on the system.
It was normal for the customer to be able to...
The part of the Trunk setting that relates to the secondary PBX must be set when connecting to the secondary PBX, which is reflected in the description.
It is also interesting that we have the experience of using profile 1 in both PBXs.
The procedure is important to do as follows:
First, connect...
Dear mr_infek,
I have practice experience with NETLINK - One SIP Trunk on the primary system and second SIP Trunk on the Secondary system.
This notice is in own language, you must translate it by google or so on, etc...
Thank you very much for the confirmation.
It helped me a lot to avoid trying to figure this out unnecessarily.
Setup using webpro with user restriction is the solution for me.
It's a real shame that you can't do it by phone, but it can be accepted.
Thanks
Thank you for this information.
Setting up the console in terms of programming using PCPro or Web Pro is problem-free.
I will try to clarify my question.
Example: I have a DT930 phone and a DCK-60 console connected to it with the console connection cable plugged in and the console is powered by...
Greeting
I have a question please.
We want to enjoy the DSS console DCK60 for the first time.
I couldn't find information anywhere on how to program single buttons using the phone to which the console is assigned.
I can do it using web pro and pc pro.
Thank you for your response.
Hi,
if it's about external analog lines, I can advise the following:
1.
Menu CO Line Settings 10.1
assignment of trunk group to lines
example 1-5 - item Trunk Group Number - setting affects outgoing calls
2.
Menu CO Line Settings 10.2 DIL Table&Port settings
set DIL destination (extension or...
Thank you for answer.
My question only concerns system DECT. I mean the DECT system operated using IP cells KX-NS0154 or KX-NCP0158. In case of KX-TDA PBX and cell KX-TDA0156 or two-wire solution using DPT port KX-TDA0155/TDA0158
The clarification of the question is therefore when using system...
Hi,
We have more than 200 customers with the Panasonic DECT system with a lot of handset, even in heavier establishments.
Changing to another system, e.g. SIP DECT, will often be quite costly for the customer
I have the following question.
Does anyone know if there is a substitute for...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.