  1. Lexzie

    OSB Individual Speed Dialing question

    I guess with OSB you mean OpenScape Business? (Better use OSBiz instead of OSB as OSB can also mean OpenScape Branch). Like you say you can dial out with *7xxxx That's exactly how you dial out. Depends on how you programmed the speed dial numbers. Have you added the route prefix for an outside...
  2. Lexzie

    OCCLA

    Not quite, If you have a X8 with OCCL (so the "old" motherboard), you can upgrade the software to V3 and still use OptiPoint 500 phones. But if you use the newer OCCLA the optiPoint 500 phones won't work anymore. The same goes for X3 and X5 systems if you upgrade the hardware to an OCCMA(R) or...
  3. Lexzie

    OCCLA

    optiPoint phones are not supported on OCCLA.
  4. Lexzie

    Call log in X8 V3

    I am not familiar with the Accounting Manager software.
  5. Lexzie

    Call log in X8 V3

    1 Have you tried Expert mode > Basic Settings > Call Charges (I have no recent experience with it). 2 What exactly do you mean? The administrator in OpenScape Business Assistant? Look in Expert mode > Maintenance > Admin Log
  6. Lexzie

    OptiClient Attendant v7.0

    I found this in my archive... https://mega.nz/file/3ixkkSgb#0itYD1EZOGevhw1V6ISqgmlPe4VzE_KNjugya8L6Et4
  7. Lexzie

    HiPath 500 and BS4 connection

    A HiPath 500 cannot be equiped with a CMA. Is the configuration done right? How many basestations have you connected to the Up0/E-interfaces? What lines are connected to the system? Is it possible to share the kds?
  8. Lexzie

    Hipath 3750 Cordless phones not showing caller ID

    Well, this is the current protofolio: https://wiki.unify.com/wiki/DECT_Handsets But your 3750 is so obsolete that there is no guarantee they will work together. The latest firmware for a 3750 is from 2009. So handsets from that time but I don't know if that was S1, S2, S3? But, almost every...
  9. Lexzie

    Hipath 3750 Cordless phones not showing caller ID

    Like I said, I remember these A-type Gigaset don't work (100%) with HiPath Cordless systems. Functionality is only supported when using the Professional handsets.
  10. Lexzie

    Malicious Call Black list feature in OSB X8 not working

    I also tried every possible form of format: F.e. if I want to block 31612345678: 31612345678 +31612345678 00612345678 0612345678 612345678 Nothing will block the call. Of course Blacklist feature on is enabled, Block Anonymous calls is disabled. System OSBiz S V3 R3.1.1_008
  11. Lexzie

    V1 to v3

    Firstly: Are you sure the mainboard is defective? Maybe only the SD card needs to be replaced. I guess you'll have to find a V1 mainboard and migrate the license to that SIEL-ID. Hopefully the move count is not 0. I doubt if this is possible on a used mainboard, maybe you can get clearance from...
  12. Lexzie

    Hipath 3750 Cordless phones not showing caller ID

    I guess this happens on all A-type Gigasets? Or do you have the same problem on other handsets too? I thought that the A-type Gigasets could not be used on a Cordless system. So that you even got them registered astonish me.
  13. Lexzie

    Hipath 3800

    I think no-one will understand what you exactly mean. Please be more specific.
  14. Lexzie

    SIP TRUNK OSBIZ X8 DIFFERENT VERSION

    No, always use the same version when networking. You might try a Native SIP-trunk.
  15. Lexzie

    Click to dial via TAPI on HiPath 3800 V9

    We have a phonebook in Google Chrome spreadsheet. It would be nice if we could dial the numbers by clicking on them. The phones have a USB-port, so we could connect them as 1st party TAPI. Anyone experience if and how to get this working?
  16. Lexzie

    optiPoint 410 or 420 connected to HiPath 3000

    The latest firmware (V5 R7.1.0) was the solution!
  17. Lexzie

    optiPoint 410 or 420 connected to HiPath 3000

    I have a OptiPoint 410 economy and a optiPoint 420 standard. 410 version V5 R6.7.0 HFA, 420 version V5 R6.5.0 HFA. The HiPath 3800 is version V9 R2.9.0_096. The HG1500 is version V9 R2.11.0. It looks like the devices are registered on the HiPath but when I try to dial an extension I can only...
  18. Lexzie

    How to remote access OpenScape Business X8 v2 via Hipath Manager E with ISDN modem?

    Did it work before on a OpenScape Business? I'm not sure if service via ISDN is still supported on OSBiz. Here we have no ISDN anymore, so I can't test it. Can you test it on another OSBiz?
  19. Lexzie

    Openstage 20 Sip firmware hilo965-1771481

    As far as I know there is no OpenStage 20 SIP, at least I don't have it and I can't download it on the Partner Portal. Looks like there is one: https://wiki.unify.com/wiki/OpenStage_20 The firmware used to be the same for OpenStage 15-40, only release notes don't mention the OpenStage 20. Use...
  20. Lexzie

    How to remote access OpenScape Business X8 v2 via Hipath Manager E with ISDN modem?

    For OpenScape Business use minimum HiPath 3000 Manager E V10, latest release now is R3.13.0. Can you answer the question if ISDN is grayed out like in this screenshot? Otherwise what errormessage do you get (if any)? (Screenshot?)