  1. Hasan UNAL

    Various problems on Option 11c

    edit: I tried MAN INT button (btw it resetted the m2250 sets) and no progress on unrecognized chars :/ I did it remotely, so I was not able to test TTY-0. BEFORE AFTER oh, pbx angel shows up again :) Yes we do have SSC card, and dip switch is on 19.200 (I changed it from 9.600 but as far...
  2. Hasan UNAL

    Various problems on Option 11c

    I have a site, running option 11c where I couldnt interract it with TTY-0. Both TTY-0 and TTY-1 is unavailable. I can only use TTY-2 for programming purposes, which was defined as printing "all recieving calls". I tried to change the octopus cable, but result was same. How to fix this and enable...
  3. Hasan UNAL

    eMG80 - CO - deny external calls

    I achieved this by; Since 9 is for “select CO in first CO group” I put gsm’s to group 2 Land line to group 1 Other pbx line to group 3 14 for special code for group 3. And digit conversation table(270) as 905–> 890205 Everyone can make call to group 3 And most of ‘em are restricted to make...
  4. Hasan UNAL

    eMG80 - CO - deny external calls

    I have 4 CO lines, 1 one of them is an extention of an another PBX. So, when users want to call a number, I dont want to make it select 4th line, only 1st, 2nd and 3rd lines. And I did a Digit conversation for selecting 4th line as; when an extention presses 9 --> outside call. when pressing...
  5. Hasan UNAL

    D-Channel Call Send/Recieve malfunction

    As per output tells, I do perfectly understand what that means. It is working fine as locally as I already posted here. The reason that I am calling IVR is that, there is no need to any human interaction for “answering the call”. I understand that every information is sent to initiate the...
  6. Hasan UNAL

    D-Channel Call Send/Recieve malfunction

    First of all, remote site is functioning great locally. Second, my main duty is developing softwares but after the nortel guy retired, I jumped into pbx systems. So, I am a total newbie in both in pbx and pbx networking. I try to figure it out from old avaya documentations. So go easy on me :)...
  7. Hasan UNAL

    D-Channel Call Send/Recieve malfunction

    I have 5 remote sites. All connected to central site. If 1. Remote will call 2. Remote site, it sends call information to central router at central site. It routes it to the destination. And also in every remote site configuration is same. Loop 2, rout 15. C lover, devoted to JS, writing...
  8. Hasan UNAL

    D-Channel Call Send/Recieve malfunction

    --Single PRI with its own DCH Here is the TRAD results. First is a Healty Remote Site. Second is the broken one. They seem to be exact! 1. Healty Remote Site ACTIVE TN 002 01 ORIG 002 01 TIE RMBR 15 1 TERM 010 0 00 12 MARP 0 4991 L500 DIAL DN 4991 MAIN_PM ESTD TALKSLOT ORIG 27...
  9. Hasan UNAL

    D-Channel Call Send/Recieve malfunction

    Hi, Briefly, I have several remote sites, and I am sitting in central site. They call any-other remote site via center router in central site. So the path is, Remote Site----> Local Router ----> Central Router ---> Other Remote Site One of them (Option11c) makes a trouble at sending and...
  10. Hasan UNAL

    SPN with 5 digits

    That's great! Maybe I should do it so. The only concerning point about this, is, the international ROUT requires FRL 4, and only attendants has that. Any other extention cannot dial directly from international ROUT. So, the system will wait until 5th number input then checks for FRL or when...
  11. Hasan UNAL

    SPN with 5 digits

    I was too desperate :) I found it HERE. In case, somebody still trying to find the solution it is ARRN. When defining an SPN, you could add alternate RLI's for tailing numbers. in my case, it is sth like this: REQ PRT CUST 0 FEAT NET TRAN AC2 TYPE SPN SPN 0539 SPN 0539 FLEN 11...
  12. Hasan UNAL

    SPN with 5 digits

    Hi, I have an issue with my local GSM operator. They define a new prefix, and it clashes with a Turkey GSM prefix: Local GSM Prefix is 0539 1xx xx xx Turkey Prefix is 0539 8xx xx xx. Since in North Cyprus, we use the same Country Code(0090), it clashes with Turkey's GSM Prefix. (PBX assumes...
  13. Hasan UNAL

    Octopus Cable Issue

    >LD 143 CCBR000 .XVR R>CCOK. (This is current back-up file - about 120KB) CCBR000 .XVR R>CCBKP002 Backup image differs from internal backup.**** (this is old backup file - about 1MB) > So, it tells it is OK. Should I trust? It is nearly 0.1 x in size... C lover, devoted to JS, writing...
  14. Hasan UNAL

    Octopus Cable Issue

    I have successfully replaced old SSC with new one, and here is the new back-up files: >LD 43 EDD000 .DAT DATABASE ISSUE DATE(d/m/y)/TIME SIZE(recs) SEQNO Main 400T 10/05/2019 at 10:20:04 72 1146 Secondary 400T 10/05/2019 at 01:00:32 72 1145 IntBackup 400T...
  15. Hasan UNAL

    Octopus Cable Issue

    The problem was, the second cable, I only soldered the red ones. Now, with all soldered it works. I have connected to SDI Port-0 and loaded a former back-up file to the new CPU. Since it is out-dated, I begin to write current configurations on it. It nearly ends. OH god, I am so happy right now...
  16. Hasan UNAL

    Octopus Cable Issue

    Cannot access to pdt. One expert come to help, but even he says, “40 years of exprience, but I never saw sth like this. It is a miracle that it is still working”, oh and also, licence was missing that day too. So he can’t build a new one. (Actually he defines everything on a new ssc but unable...
  17. Hasan UNAL

    Octopus Cable Issue

    Here is my drives. They are literally don't answer on any request. >LD 43 EDD000 .DAT DATABASE ISSUE DATE(d/m/y)/TIME SIZE(recs) SEQNO Main database not accessible. Secondary database not accessible. IntBackup 400T 14/02/2014 at 01:00:34 70 1126 PCMCIA database not...
  18. Hasan UNAL

    Octopus Cable Issue

    One of my Option11 is currently dying. (His doughterboard is dead). No Back-up, no PCD or anything else. So, I started to build up a new CPU according to it. But the issue is, neither I nor the local market have an octopus cable (In North Cyprus). So, as instructed here, I have tried to make a...
  19. Hasan UNAL

    List Busy Extentions

    [Question] Is there a way to list busy extentions? [Description] The problem we having is, there is a cabling problem, and time to time, some of my extentions are hanging in space. And they are making my operators crazy. This (answer of my question) will be a relief, because you know, in the...
  20. Hasan UNAL

    CS1K Console Programming to Advanced UI

    The thing is, my organization will keep these systems for a while. [Funds and stuff]. My approximation is at least 3 years nortel's are with me. I have to do the administration and maintanence of these systems in following years. Thus and so... C lover, devoted to JS, writing c#... Nortel...