Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Ghoulam

    New PCM line creation problem

    Ok guys problem resolved. I had to erase the board and re-initiated again, and then the PCM line was created normaly Sorry for the post.
  2. Ghoulam

    New PCM line creation problem

    here is other commands that may help: <ilssp; BPOS GSMULT SIGN LINK STATUS LINK CAPABILITY 001-0-00 0-00 YES OKAY LONG 001-1-00 0-04 YES OKAY LONG 002-0-00 0-01 YES OKAY LONG 002-1-00 0-05 YES...
  3. Ghoulam

    New PCM line creation problem

    Hi everyone I have a TSW sp8 of 3 lim, running from 2007, 2 lims on the same site and the third one on a remote one, conected through a xDSL line, but in 2007 we configured only one junctor 3-0-00 to gsmult=0-6, I need now to add the second junctor line through 3-1-00 to gsmult=0-2. here is the...
  4. Ghoulam

    Strange problem

    Thanks montyzummer for your answer, I tried a cold reset, the problem appears less often now, but it's still here. What do you mean by brandy output? regards
  5. Ghoulam

    Strange problem

    Hi everyone I have a strange problem with an Aria SoHo 9/32. Sometimes, when the digital extension 101 terminates a communication, the Digital extension 104 start doing a busy tone alone, or a call-back tone is initiated on the OP (100) and vice versa. The system is in the last version 3,9 Cb...
  6. Ghoulam

    Aria Soho &amp; SMS

    Hi Evryone I would like to know how does Aria Soho use SMS, all aria brochures talks about SMS, but when you read the user or installer manuals it's not clear. The programming is quiet OK: PGM 291, but how do we write the SMS to send it through the CO line. For installation I imagine that we...
  7. Ghoulam

    BML351041 and BML351011 differences

    Hi guys I want to know the diffeerence between BML351041 and BML351011? is it the same product in new version only. Because I have to change a BML351041 (PE2143) on a MD100 BC12 system, I found the same one at 600 euros and found BML351011 at 92 euros, if I can use one or the other it's very...
  8. Ghoulam

    BP 250 ANALOG trunk(v-sat line)

    May be you can try to change the parameters of the the trunks, change between DTMF, MFC... and see Did you try it yet?
  9. Ghoulam

    No tones on the phones

    Yeg all the phones lim1 & 2, digital & analogs I don't have HIMDP sorry the date is wrong here are all alarms: <ALLIP; ALARM LIST IDENTITY: EPC-1ALGERIA VERSION: CXP1010123/4/TSWSP03/R4A DATE: 22MAY13 TIME: 15:31:08 CODE CLASS NOAF EXPLANATION 15 2 1 DEVICE BOARD FAULTY...
  10. Ghoulam

    No tones on the phones

    Hi guys I have one MD110 TSW SP3 version, there is no tone on all the phones, and when you call any extension; it rings one time and then stop, but the communication is established, Is it the TMU board, that can do these two problems, I found an alarm about TMU but it's class zero: 324 FAULTY...
  11. Ghoulam

    French docs &amp; language

    Sorry the system is TDA620 for the second question
  12. Ghoulam

    French docs &amp; language

    Hi everyone Does somebody knows any web site where we can download panasonic documentation in French? I wondered also if we can change screen language on DPT phones to french only by programming or is it a soft I have to add on the system? Thank you all
  13. Ghoulam

    BP250 DDI number translation

    Ok man, thanks a lot, that was very helpful
  14. Ghoulam

    BP250 DDI number translation

    Ok Now I understand, but this is when you have two different links which means two boards, but is that possible on the same ISDN link (30 trunks)???? I don't think so. At least I understand now the utility, it's useful when you have two or more links, am I right??
  15. Ghoulam

    BP250 DDI number translation

    I still do not understand, maybe because in our country we are not use to digital trunks! It's new for me. How can I use trunk 700 for ddi1 and trunk 702 for ddi2, I thought that in digital trunks it was impossible to do that since the trunks are fictive and not physical as on analog ones...
  16. Ghoulam

    BP Soft &amp; firmware download site

    Yes I know where to get them for Panasonic or LG-Ericsson too, but for Aastra, it's more complicated I think! Google desn't know anything about those firmwares.
  17. Ghoulam

    BP250 DDI number translation

    hi guys I need to know what does DDI1 & DDI2 stand for in command 2260 on BP250. I know its the last digits of the DDI number but why there is two, DDI1 and DDI2? I cannot understand also the meaning of the translation table in command 2260, does the first column of internal directory number...
  18. Ghoulam

    BP Soft &amp; firmware download site

    I'm certified on BP products (250,128i, 50), but the compagny where I'm now is not an aastra distributor, that's why I have no access anymore. Thanks both thow.
  19. Ghoulam

    BP Soft &amp; firmware download site

    Hi Guys Is there any web site where we can download Ericsson (Aastra) BP250 software & firmware, I can not access to my dealer web page anymore. I need CPU-D4 R18 soft if possible! Regards
  20. Ghoulam

    CPU-D4 R11 with FECU R12

    But why the R12 FECU is not recognized by R11? It's not supported?

Part and Inventory Search

Back
Top