Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: rg5dc
  • Order by date
  1. rg5dc

    MD110 BC11, LIMs stuck at "30" on LogDisplay...

    Thanks for the response, but I didn't quite understand it. I think that 3310, 3320 on I/O LIM passed OK. LIM2 and LIM3 are in "30" because they are waiting for I/O LIM to start loading them... What bugs me is why LIM1 is showing "30", probably because of no valid REL directory...
  2. rg5dc

    MD110 BC11, LIMs stuck at "30" on LogDisplay...

    I will try to fix this error on Monday, but it would be nice if someone advise what to expect on site and which boards I should bring as a spare parts... It is a 3-LIM system, all LIMs are at the same location (I think that it is a multi-lim system because of the total capacity...). Not seen...
  3. rg5dc

    EXL in NAPTS lenght

    I have a working scenario with EXL lenght of 10 digits (which is a max No of digits for EXL). Problem is that I need to change this EXL to 13 digits. Is there a way to do this? My EXL contains DEST+provider access No (eg 123+1234567 - now it is 10 digits total). Provider will change his access...
  4. rg5dc

    SPU

    As far as I`m aware, SPU (SPU4 to be exact) is used as DTMF receiver or for RVA. I don`t understand when you say "I try to call to SPU". I would like to know more details about this, please.
  5. rg5dc

    NIU2/12 in LBP20 with BC12

    I`m sorry for noobish question. Of course ceejay55 was right about port that should be used for connecting. As I said (and was wrong), I was using highest tty port which is No.3 After changing to lowest tty, all is OK. Thanks for pointing the obvious to me!
  6. rg5dc

    NIU2/12 in LBP20 with BC12

    I`m using tty1 port like before (top RH45). I`ll try the procedure one more time and put REL1 for 1-0-60, and see what`ll happen. Thanks for reply!
  7. rg5dc

    Ericsson 4223 phone displays fastly dying

    I`m aware of this problem and E/// advice, but it doesn`t make sense, cause in my case even the newly shipped 4223s are dying. It is true that the new ones die in less quantity, but that is horrible from advertising point of view. The 3xxx series newer had any problems what so ever (you could...
  8. rg5dc

    NIU2/12 in LBP20 with BC12

    Hi, I`m trying to load the INL on to new NIU2/12. After writing the EIC, and IP setup, I`m using FTP to copy the INL. All is OK and after a restart, MD is loading from INL (it starts from "60" and stops at "101"). So far so good, but when I try to connect, there`s no USER/PWD prompt! As far as...
  9. rg5dc

    3 lim system, weird error!

    I solved the issue from the OP! I checked the grounding on LIM 3, it was OK. I could hear some buzzing sound coming from rg5dc, so I blocked and turned off lim 3 and replaced the board. After starting the 3rd lim, it wouldn`t see GJUL and couldn`t start at all (2700 on lpu display). Since I was...
  10. rg5dc

    3 lim system, weird error!

    @doktor I`ve seen your instruction in one of posts regarding grounding. As I said, I will check that also, but FYI, LIMs are on different locations and were properly grounded when installed. Thanks for support!
  11. rg5dc

    3 lim system, weird error!

    Did some research about LALRL, and will try it. In the mean time I`m posting some printouts for reference: [code] [small] <CADAP; CALENDAR DATA IDENTITY=HET VERSION=CXP1010101/4/TSWSP04/R5A 08:48:23 FRI 13 NOV 2009 END <ALLOP; ALARM LOG IDENTITY: HET VERSION...
  12. rg5dc

    3 lim system, weird error!

    Thanks for instructions Daddy! I`ve never even read about this command before, so I need to check it first (educate myself) and then try it and comment. I`ll for sure try to do a data backup before anything else and even go for SP6. Thanks again!
  13. rg5dc

    how to upgrade and restore for system

    You really need to be very careful before deciding to do it your self. Get to know more about the system and I must agree with "ceejay55" - do some trainig first! I can only tell you that my approach is - start from INL! This maybe the slowest path, but it worked every time for me. BR, Igor
  14. rg5dc

    3 lim system, weird error!

    I have 3 lims, and each one have digital, analog and DECT extensions. Connected via GS using one PCM link toward each lim. System is TSW-SP4, HW is in LBP20 (all boards are from earlier HW release, just SW was upgraded from BC 12 to TSW). System worked flawlessly for 2 years after upgrade and...

Part and Inventory Search

Back
Top