Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Fleisch

    LD not working on just a small range?

    I actually had a situation like this happen to me a few years ago and for some reason the DID number was flagged by the LD carrier's toll fraud department because they did not have them assouciated with an account. I would start there if you're saying that you just assigned an new PDN on the...
  2. Fleisch

    SPN 011 - Opt11C to DMS-100 NI-2

    This is a copy of my current working dch but I think it is a 5E at the far end. ADAN PRIM DCH 5 BDCH 6 CTYP MSDL CARD 01 PORT 1 DES VERIZON USR PRI DCHL 1 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT IFC NI2 ISDN_MCNT 300 CLID OPT0 CO_TYPE STD SIDE USR...
  3. Fleisch

    Locked out of a callpilot

    you're saying you reset the mailbox and you can't get into it? You can dial to it and it is asking for a password? Did you check the "Messaging"- "Security Administration" in callpilot and see if there is a prefix set for default passwords? The new mailbox password or a reset mailbox password...
  4. Fleisch

    CDR not coming one route

    I'm pretty sure that if you change CDR options on route, you need to initialize for them to take effect.
  5. Fleisch

    SPN 011 - Opt11C to DMS-100 NI-2

    I had maybe a similar problem with a Verizon Business PRI a couple of years ago. Although the implementation manager swore up and down the PRI was set to handle INTL calls, there was a some restriction table on their end that needed to have our DID number range added to. The only way I ever got...
  6. Fleisch

    Caller ID not showing to external party

    Here's a copy of mine and I pass digits. It looks slightly different than your CLID entry. ENTRY 0 HNTN 212 ESA_HLCL 503 ESA_INHN YES ESA_APDN YES HLCL 503 DIDN YES HLOC LSC CLASS_FMT DN
  7. Fleisch

    Call Forward (CFWD) to a long distance number

    There are several things to look at here Trunk in NCOS. Do you have CFF or CFO in CDB Net_data Ncos of the set plus CFXA in CLS and CFW 12 on key Also- FRL on the RLI for the number going out. If the call in starts on a trunk with a ncos of 0 and then is being call forwarded using CFO, when it...
  8. Fleisch

    Not hunting up keys

    Why don't you just change 2617 to a MCR (multiple call ring) instead of SCR and put it on both phones. Call comes in-rings on both phones-the 1st phone answers the 1st call, 2nd call in would ring on the other phone while the 1st line is busy instead of all that hunting. remove FDN and HUNT and...
  9. Fleisch

    redial for an outside call

    check to see if you have LRA in FTR_DATA block in the customer data block. It would be in the OPT line.Do you have LNA in the CLS of the phone? LNA on the phone should allow you to redial the last number by hitting the extension key twice.
  10. Fleisch

    Set Time and Date

    day month year hour minute second

Part and Inventory Search

Back
Top