Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: lmman
  • Order by date
  1. lmman

    Optipoint label template

    I'm looking for a template for printing out labels for an Optipoint 500 set and its extra button add on module. Thanks in advance for any help.
  2. lmman

    PRI from Opt11 to BCM450

    Customer bought the keycode and the PRI came right up. Thanks everyone for the advice!
  3. lmman

    interfacing a channel bank?

    I have a customer who has a BCM400 who would like to extend some lines through a channel bank. My question is how do I assign a number to a trunk on a T1? Currently we have a T1 built and interfacing a channel bank, but am not seeing where I can have certain numbers hit a a specific channel...
  4. lmman

    PRI from Opt11 to BCM450

    Do I need to get the MCDN keycode FOR A BCM to talk to an Opt11? My research makes me believe I only need that keycode if I want to share a voice mail.
  5. lmman

    PRI from Opt11 to BCM450

    I started off with SL1 for that reason, but the BCM guy I am working with says he only has options for NI2, DMS 100, and ES55. I'm not terribly proficient at the BCM, but can you give me some info on activating the MCDN code? Or is this a Keycode they will need to purchase? Thanks, and other...
  6. lmman

    PRI from Opt11 to BCM450

    I have a customer with an Option 11 and they want a PRI from it to a BCM450. The PRI comes up and I can see all the channels & D-CH. Below is the build of the PRI, trunks, and D-CH. I'm not doing any digit manipulation, but have 1 range of numbers pointed to the PRI. When I dial a number...
  7. lmman

    How to Setup Paging

    Check the TGAR on the phone your testing from. If its set to 1 you will get a busy. If thats the case I would remove the TARG 1 in the RDB.
  8. lmman

    Option 11 PRI

    I've got an Opt11 that I have programed a PRI for interfacing to a BCM50. The span is not comming up, anyone know how this should be programmed?
  9. lmman

    Internal calls not working?

    I dialed in and didn't see anything before heading out to the site. As it turns out the customer experienced a brown out and some of there network equipment failed effecting the IP sets. I doubt the digital sets ever had a problem.
  10. lmman

    Internal calls not working?

    I have a customer who is telling me they can not make calls internally from 3904 sets to other 3904 sets. They also say they cant make internal calls across any of there IP sets. I can think of reasons why IP sets might have that problem, but what might cause this with the digital sets?
  11. lmman

    CS1000M & Element Manger question

    Thanks for all the feedback. Was able to get to Element Manager with your help.
  12. lmman

    CS1000M & Element Manger question

    ok, whats the best way to find the TLAN IP address in a system thats up and running? I believe its 4.5w and not sure right off what sig server they have
  13. lmman

    CS1000M & Element Manger question

    HOw do I get to the Element Manager on a CS1000M? Is it software that needs to be installed on a PC somewhere or is it on the CS1000? Thanks
  14. lmman

    Compact Flash

    Thanks guys
  15. lmman

    Compact Flash

    I've misplaced my PCMCIA card and Compact Flash. Will any Compact Card flash work in a CS1000? I've got to upload a deplist and in a bit of a jam
  16. lmman

    Rolm 9751 backup

    I've got a couple of Siemens/rolm 9751's that I have to do a backup of them and there VM. one is mod10 and the other is mod 50. What all do I need to get this done? Thanks in advance lm