Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Sygi
  • Order by date
  1. Sygi

    Openscape Office MX - old hipath Open office

    Hi guys, I'm trying to connect external apllication to my Hipath Open Office ( Openscape Office MX - right now ) use'ing CSTA protocol, and it wont work... I have done it with hipath 3000 with any problems ( user: AMHOST, pass:77777 port 7001 ) but here with Open Office these parameters are...
  2. Sygi

    STMI2 HG1500 ip connection lost

    Probably ur card is damaged. Maybe try low level format tffs memory use'ing boot CLI or disable alive monitoring ( web management ). greetings Pawel Sygula
  3. Sygi

    OptiPoint 420 Stuck in 'Initializing'

    U need such thing as boot server for optipoint, only Siemens engeeniers have it, and they wont share it. It is a program that upload to your phone new boot config - because your is damaged ( it happend ). probably u can't do anything with it, except send your phones to service. greetz Pawel Sygula
  4. Sygi

    HG 1500 v2 hipath 3550 v4

    I get solutions, in market there are two types of hg v2 boards. One is only for data ( downloading kds from manager ) and second type is for networking and data. When i replace the card it works fine... bye Pawel Sygula
  5. Sygi

    can´t send DTMF tones to an IVR

    Probably u need to upgrade your hipath to an latest version. I know that there is problem with sending dtmf tones beetween two hipath's in ip network as same as problems with MOH ( u wont hear music from another pbx :( ). I've got the same problem with hipath 3000 v7, and it just dont work...
  6. Sygi

    HG 1500 v2 hipath 3550 v4

    Hi again, I have done all this steps that you wrote. My Hg looks like working fine because i'm downloading data over IP network. I think that maybe this card is bad - because when i type trunk code - i get "unavailble" instead signal. In all my others hg ( v3.0 ) when i type trunk code i always...
  7. Sygi

    HiPath 3000 V6 with TAPI 170 V2

    HI Ithink that maybe is a server problem in readme file from tapi1770 v2 there is no message about supporting windows server 2008 ( its supports win 2k, 2k3,xp, vista ). But there is information about not supporting 64 bit sytems, is your server is 64-bit ? greetings Sygi
  8. Sygi

    HG 1500 v2 hipath 3550 v4

    Hi all, I have problem with ip trunking in hipath 4.0. I'm using hg 1500 v2 ( with 2x Lan interfaces ) I'm trying to connect to other hipath but even when I dial trunk code i get busy. I compare config of these to hg cards and it is identical but in manager E i see "V" letter next to ip address...
  9. Sygi

    Siemens HG 1500, Hipath 3500, SIP and NAT problem

    Hi, it is problem with routing for voice packets. The best way is to use VPN connection or set HG to a public IP. When u do that, you just have to set the lan2 interface and in the local area network put registration for nokia thru lan2 interface. Should work. bye Sygi
  10. Sygi

    Paswword for Hipath OpenOffice using SSH ?

    Hello Does anyone know login and password for linux built in Hipath OpenOffice - i'm trying to get to my Hipath using SSH for change default phonemail messages ( such as in EVM - please wait etc. ). I have done it in OpenScape Office, but there i'm instaling linux by myself - linux in hipath...
  11. Sygi

    Qsig on Hipath 3000

    Hi Well i did it beetwen 2 hipath's. It works fine, of course one of the pbx have to be master and the other slave. You have to create a seperate route for connected pbx's. And type of this route should be pbx. Are you using LCR ? if yes you have to configure it properly. If you have some...
  12. Sygi

    Siemens AP1120

    Hello dneis AP 1120 H.323 is very simple to configure, but the mnual is horrible. I can send you an email with screenshot with configuration of AP 1120. Unfortunately I Don't know how to add a jpg file to this post :) My email is sygi1@wp.pl greeetings BTW sorry for my english...

Part and Inventory Search

Back
Top