Hi,
I have a 2901 router which is showing some odd behaviour. During the evening/night/weekends when there is no load on the CPU or WAN link the response times to the router over the network becomes quite high, anything between 200 - 600ms. The normal response time during the day when it is...
Hi,
I have a PRI circuit between 2 Option11s and am getting the following error at one end
PRI2 LOOP 1 - ENBL
REF CLK: ENBL
TRACKING
SERVICE RESTORE: YES
ALARM STATUS: OOS LOCAL ALARM : LFAS
CH 01 - DSBL TIE VOD * CH 02 - DSBL TIE VOD *
CH 03 - DSBL TIE VOD *...
This is the trunk that i dont get busy tone from
YPE RDB
CUST 00
DMOD
ROUT 110
DES EURO ISDN
TKTP DID
NPID_TBL_NUM 0
SAT NO
RCLS EXT
DTRK YES
BRIP NO
DGTP PRI2
ISDN YES
MODE PRA
IFC EURO
CNTY UK
SBN NO
PNI 00000
NCNA NO
NCRD NO
ISAR...
There is no loops etc as the only place it has been forwarded to is itself or no forwarding at all.
After further testing i have found it gives busy tone on internal calls and from an IP incomming call, so it looks like it might be a trunk setting.
Hi,
Thanks for the advise, but neither worked. I was initially thinking it was just with this set, but its the same on others, so im now thinking its a system wide issue.
is the busy tone set in the trunk anywhere perhaps?
Hi,
Im sure this is a simple issue and its staring me in the face. I need a 3902 to give busy tone when its busy. At the moment all it gives is the continuous dead tone when the phone is in use.
I have tried the phone with no forwarding of any sort, just FDN set to forward to itself and all...
Hi,
Both Meridians have the following in NET
DITI YES
TRNX YES
EXTT YES
FTOP FRES
and neither have XFA in the CLS as they are digital exts, my understanding is that is a 500 set CLS.
Ive already tried UNR and that didnt work. The thing that concerns me is that the Meridian is letting him dial out but only seems to be sending the 00 part of the number.
This is the only phone on the Meridian that has ever been allowed to make international calls so i cant compare it to a working TN unfortunatly.
The international number being dialled is the correct number as it works from other places. The number being called is 00 353 xxx xxx, so its not...
Hi,
I have a single 3903 set up to allow international dialling but it has stopped working. The NCOS allows international dialling and i have tested this by changing the NCOS on the set to a different class. When it has a international barred NCOS it doesnt allow the call, but with the allow...
Thanks for that. Ive looked at both systems and they both have the following set
CDB
Net Data
TRNX-YES
EXTT-YES
A set from the system that can transfer has FTTC in the CLS and a set from the system that cant has FTTU.
So neither of these settings seem to be the one that is stopping the...
Hi,
I have a customer with 2 Meridian Opt 11. running 25.15. On both systems they can call mobiles and national numbers, but one cant transfer calls to mobiles and national calls. They want this implemented on the other, but i have no idea how thats set up.
My understanding was that when a...
Hi,
I have been asked to perform a remote backup of a BCM400 3.6 and the only access is via ISDN dial up. I can dial into the BCM and access the BRU utility and set up a backup the same as i would do a remote backup over a network, but it is not working. It cant access the network. The BCM...
Here is a print out for the RDR_DATA, but i cant see anything that relates to transfered calls.
REQ: prt
TYPE: rdr
TYPE RDR_DATA
CUST 0
TYPE RDR_DATA
CUST 00
OPT CFO CFRA DSTD PVCA CWRD
FNAD FDN
FNAT FDN
FNAL FDN
CFTA NO
CCFWDN
CFN0 6
CFN1 6
CFN2 8
DFN0 6
DFN1 6
DFN2 8
DNDH NO...
Hi,
Im running an Option 11 R25 Issue 11 and am having a problem with call transfers.
The user answers a call and transfers it to another phone, if that phone isnt answered and they take the call back and take a message 2 things happen. Firstly, the phone they tried to transfer it to keeps...
More info.
Apparently this problem happened a few months back and after the system was rebuilt it with a new SSC card it was still doing it. After replacing the PSU it stopped, but has now started again.
The users have also now complained they are getting crossed lines from within the...