Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. miditsupport

    BCM50 PRI incoming ringing problem

    Yep, I realised that I was browsing the wrong forum after I posted the question so re-submitted it!
  2. miditsupport

    BCM50 OLI, PRI

    So as to present the full STD number, i.e. 01234 567890
  3. miditsupport

    BCM50 OLI on isdn30

    Hi Snowman, You're quite correct, the service main number is usually automatically presented as the main OLI. However, in the past I've asked BT to change this to one of the DDI numbers which they did. The trouble with that is that (as Firebird correctly pointed out) BT isn't the account...
  4. miditsupport

    BCM50 with PRI, incoming ringing problem

    Ah, answered my own question! The broadcast hunt group and target line did the trick!
  5. miditsupport

    BCM50 OLI on isdn30

    Oh, I forgot to say.... the ISDN30 is using 8 channels with a common or garden variety number which is far from memorable. The (non BT) service provider has provided the customer with a geographical 'cloud' number (not a DDI range as such). This number is ported to the ISDN30 headline number...
  6. miditsupport

    BCM50 with PRI, incoming ringing problem

    I've got a problem with a BCM50 fitted with PRI ISDn30 only ringing extension 221 (via target line 125). Ring group 001 has all of my extensions in it and has all the target lines allocated but not trunks 65-72 (I suspect this is correct). What's the correct procedure here for setting up...
  7. miditsupport

    BCM50 OLI on isdn30

    I need to present a full 11 digit STD DDI number as the main outgoing ident for all og calls on my PRI equipped BCM50. I tried changing the public network received number length to 10 and then entering the number (minus the leading 0) as the OLI but this didn't seem to work. I noticed that...
  8. miditsupport

    BCM50 OLI, PRI

    Oops, sorry, wrong thread. Moved to the BCM thread!
  9. miditsupport

    BCM50 OLI, PRI

    I need to present a full 11 digit STD DDI number as the main outgoing ident for all og calls on my PRI equipped BCM50. I tried changing the public network received number length to 10 and then entering the number (minus the leading 0) as the OLI but this didn't seem to work. I noticed that...
  10. miditsupport

    BCM50 PRI incoming ringing problem

    I've got a problem with a BCM50 fitted with PRI ISDn30 only ringing extension 221 (via target line 125). Ring group 001 has all of my extensions in it and has all the target lines allocated but not trunks 65-72 (I suspect this is correct). What's the correct procedure here for setting up...
  11. miditsupport

    BCM50 R3 ISDN30 PRI No Dial Tone

    Ahah! Yep, that makes sense! Have reprogrammed as you suggested, working fine! Thanks!
  12. miditsupport

    BCM50 R3 ISDN30 PRI No Dial Tone

    Ah, Sorry, I should have been a bit clearer! When I press 9 for a line I get the message 'no free lines'.
  13. miditsupport

    BCM50 R3 ISDN30 PRI No Dial Tone

    Hi Guys, I'm probably missing something really silly but I've got a newly provisioned ISDN30 PRI circuit connected to my DTM-PRI MBM in expansion chassis 1 (on a BCM50 r3) and I can't get dial tone (9). It's properly configured in Telephony Resources as DTM-PRI, enabled and the correct 8...
  14. miditsupport

    Relocated HiPath 3300 incoming ring problem

    Thanks for the info. Unfortunately, the system had been well and truly locked down by the previous maintainer so no joy there. In the end we had to resort to defaulting the system and reprogramming (with the able assistance of another company with the correct kit). All working OK now and the...
  15. miditsupport

    BT Versatility....

    Morning all, someone suggested that this may be a firmware issue. Could anyone confirm this? I'm currently running 831
  16. miditsupport

    Relocated HiPath 3300 incoming ring problem

    Hi All, before I start, I have to confess that, being an ex BT engineer, I know b*gger all about the Siemens range of HiPath systems. I've just had to relocate the afore mentioned HiPath 3300 to a new office about 10 miles away in an adjacent telephone area. The system still has two ISDN2...
  17. miditsupport

    BT Versatility....

    Yes, seen this chap's website before. I've got all of the technical information already but can't see if it's possible to make a DDI ring a specific button. I thought that asigning it to an incoming calling group was the answer but unfortunately it just rings as an incoming line on the line buttons.
  18. miditsupport

    BT Versatility....

    OK, this isn't a BMW related query, honest! I've a bit of a puzzle to solve. I've got a Versatility with ISDN2 and an SN-DDI. I need this DDI to ring as an incoming line on a dedicated button on several V8 phones. The only way I can think of doing this is to program the DDI to ring a new ring...
  19. miditsupport

    BT Versatility

    Morning David, Thanks for your kind offer of the software and firmware, I already have the engineering version of the Ovida software! I upgraded the system that I'm working on from 851 to 887 in an attempt to fix the problem but to no avail. I was hoping that the later software may have a bug...
  20. miditsupport

    BT Versatility

    Ok ok, don't shout at me, I know this is the BCM forum but I'm hoping some of my BCM collegues out there may be able to help me here! I need to obtain the latest firmware for the BT Versatility phone system - 915 I believe but any 9xx will suffice. Have searched everywhere and zip-all seems to...