  1. poq

    IP500 V2 rel 8 (SIP TRUNKS / CODECS)

    Hey guys, thanks for your help. Problem solved. Solution: Removed the VCM30 that was in the Legacy Carrier. Removed the Digital Station 8's. Used (1) IP500 Combo Card. Looks like all 10 VCM Channels inherent on the Combo Card are live. The Twinning is working as well. Must have been...
  2. poq

    IP500 V2 rel 8 (SIP TRUNKS / CODECS)

    I am still unable to get the Digital Sets to grab the Line Group of my Sip Line. I have a VCM30 sitting on a legacy carrier as the VCM Resource. Is the VCM30 Compatible with SIP Trunks? Maybe I need the VCM32? My montior is telling me the following after attempting to make a call from a...
  3. poq

    IP500 V2 rel 8 (SIP TRUNKS / CODECS)

    Also, I don't know if this is any indicator of anything but I am unable to use Mobility Twinning on the working IP Phones. I upgraded my system from 6.0. I retained the Preferred Edititon (Voicemail Pro) License. Is this also accepted as the Preferred License. (i beleive preferred is required...
  4. poq

    IP500 V2 rel 8 (SIP TRUNKS / CODECS)

    I have my System Status open. - It is showing that I have 30 VCM Channels with 0 in use at this time. - I placed a test call from an IP Phone to a Digital and the System Status showed 1 VCM Channel in use at 3%.
  5. poq

    IP500 V2 rel 8 (SIP TRUNKS / CODECS)

    I am communicating with my remote IP Phones from digital phones within the office. I have the following setup: IP500 DIGITAL STATION 8 PHONE2/ATM4 CARRIER/VCM30 ** I don't believe that I would be able to talk to my Remote IP Phones if I didn't have any VCM Resources? Just a thought.
  6. poq

    IP500 V2 rel 8 (SIP TRUNKS / CODECS)

    I am installing SIP Trunks on an IP500V2 rel 8. (4 Channel Broadvox Trunk to be exact). 1. I followed the Avaya Instructs to the "T" on installing SIP Trunks. 2. I am using an available Static IP. 3. I am bypassing the Company Sonicwall Firewall, I am going Direct from Comcast modem to LAN2 /...
  7. poq

    Distance IP500 to Digital Phone

    Hello, Can anyone kindly tell me the Max Distance that you can run a Digital Phone from an Avaya IP500 V2? And if I exceed that limit is there some sort of repeater that i can purchase that work on digital station lines? Greatly Appreciated!
  8. poq

    8x24 - Centrex Plus Software - NRU10 backup restore

    I am trying to do a backup restore on an 8x24 that is running centrex plus software by using NRU10 or 11. My customer wants to upgrade to the 5.1 software without having to reprogram. Can anyone tell me if this is possible or if this is can be accomplished any other way. thanks!!
  9. poq

    CALL PILOT 100 ERROR CODE

    7.1 software, mics, connected to one station.
  10. poq

    CALL PILOT 100 ERROR CODE

    So, bootloader in bottom slot. power up, go thru cycle. hyperterminal says bootloader finished... power down, take out bootloader, insert software and power up?
  11. poq

    CALL PILOT 100 ERROR CODE

    Tried that one.
  12. poq

    CALL PILOT 100 ERROR CODE

    Yes, I am connected to a working system. We have experience with these units. The message is still the same after one hour. Other units are linking up fine when tested in the place of this unit.
  13. poq

    CALL PILOT 100 ERROR CODE

    Hello, Item: CallPilot 100 Software: 3.1 Issue: We have the unit connected via hyperterminal. We are getting the following error message when doing a start up. --------------------------------- Login: Starting Access/2 and Voicemail SysConfig file does not exist. Use default!!! Open File Error...
  14. poq

    i2004 phone re-cycling

    Hello, I have an i2004 phone that i am linking in remotly to my bcm200. Here is the sequence of events. 1. Power it up. 2. Phone shows downloading firmware 3. Phone links up. 4. Phones resets and starts from step 1. Any help would be greatly appreciated. Thanks.
  15. poq

    BCM 200 Remotly accessing everything but CONFIGURE

    Ok. Logging in. Here is what i see... Shows: "In Progress" for about 3 mins. Then it shows: " [Connection Failed] Failed to connect to BCM server" And that's it.
  16. poq

    Had Door phone and Opening Controller on MICS now on BCM it wont work

    But there isn't a Nortel Door Phone that works on the BCM50... correct?
  17. poq

    BCM 200 Remotly accessing everything but CONFIGURE

    Yes, Java is installed, the Java portion loads fine, the username and password comes up fine. After entering the user name and password the i get a message after about 3 mins that says disconnected. however, at that same time, i can connect to the voicemail, the wizzard, the BRU etc.
  18. poq

    BCM 200 Remotly accessing everything but CONFIGURE

    Hello, I can access the BCM200 "Business Communicaton Manager" just fine on the customers static ip. I am able to access the Wizzard, Install Clients, CallPilot, Doc, BRU, Maintenance, etc. HOWEVER, I AM NOT ABLE TO ACCESS THE CONFIGURE (system administration & management) button when...
  19. poq

    BCM wav file import to CallPilot giving server error!

    Hello, I am trying to upload a .wav file to the individual mailboxes in the call pilot manager. The system keeps giving me an error message. "Server Error" Any ideas? Thanks in advance.
  20. poq

    PC FAX messaging on a MICS w/ Callpilot 150?

    Hello, Is there any way to send and receive fax's from individual pc's that are run by a MICS/with-T1/r7.0-software/CallPilot150/Unified-Messaging? Thanks in advance.