  1. waynehamm

    FDN for internal calls not going to voicemail

    Sorry for the long delay in answering. I have run some tests today to see what happens when I try different things. Transfer to 1616 - allows me to get the message asking for mailbox. On the phone Im transfering to busy the two DNs and then transfer and it goes to the mailbox. Set CFW to...
  2. waynehamm

    FDN for internal calls not going to voicemail

    Call Server / MAIN CAB Version 2121 Release 3 Issue 00 + I made the changes to MDID YES NDID YES MWFB YES and I'm still getting bounced back.
  3. waynehamm

    FDN for internal calls not going to voicemail

    Well, I created an CDN 2400 and pointed the DFDN to 5500. Now if I call through the DID it just rings, from the AA it just rings and when transfered it goes back to the person that did the transfer like before.
  4. waynehamm

    FDN for internal calls not going to voicemail

    I have tried to change the HUNT and FDN to both 1617 which is the express messaging and also 5500 which is the ACDN of the Callpilot. Its weird that if you dial the extension from the Auto Attendant or use their DID it does go to voicemail. Here is more info on the CDN 1616 REQ prt TYPE cdn...
  5. waynehamm

    FDN for internal calls not going to voicemail

    Sorry for my ignorance but for transfer recall timer is the below what you are looking for? Also I tried this (Was rtim 30 30 30) but I was told it will only work for 2250 console. ld 21 REQ: prt TYPE: tim TYPE TIM_DATA CUST 0 TYPE TIM_DATA CUST 00 FLSH 45 PHDT 30 DIND 30 DIDT 14 LDTT 6 BOTO...
  6. waynehamm

    FDN for internal calls not going to voicemail

    How do I find the transfer recall timer? The RDR_DATA is TYPE RDR_DATA CUST 00 OPT CFF CFRD PVCD CWRD FNAD FDN FNAT FDN FNAL FDN CFTA NO CCFWDN CFN0 4 CFN1 4 CFN2 4 DFN0 4 DFN1 4 DFN2 4 DNDH NO MDID NO NDID NO MWFB NO TRCL 0 CRT0 00 00 00 00 CRT1 00 00 00 00 CRT2 00 00 00 00 CRT3 00 00 00 00...
  7. waynehamm

    FDN for internal calls not going to voicemail

    Hello, I hope some one can help me out I'm having an issue with calls that are transfered from one set to another on the same switch will not go to voicemail but back to the person that transfered the call. If someone calls the DID number from the outside it will go to voicemail and if the DN...
  8. waynehamm

    How to Setup Paging

    Thank you guys.... I have changed SUPN to NO SUPN YES <---Changed to NO It is now working. My conclusion is I messed up and didn't test 78 properly since I did have SUPN set to NO on it. The CLS set at CTD works fine for me. Thanks Again Guys for all your help.
  9. waynehamm

    How to Setup Paging

    telebub - I disabled and renable the TN and Im still getting the fast busy tone. Currently unable to reseat card. GHTROUT - I'm just dialing 699 nothing after or before. I have tried 78 and 2 as well. All of these were listed as unused. I have also tried 3 5. Print out of route REQ...
  10. waynehamm

    How to Setup Paging

    telebub - I'm connecting straight to a Amplifier. GHTROUT - I have tried both with the port connected to the AMP and without it connected to anything and I'm still getting a fast busy tone.
  11. waynehamm

    How to Setup Paging

    Thank you for your posts so far. I verified the TN is not disabled. REQ: stat 3 6 IDLE I Changed the CLS to DTN with no luck I Changed ACOD to 78 and 2 with no luck I will try a matching transformer. If I disconnect the line to the AMP should it then ring? becuase I get the same issue...
  12. waynehamm

    How to Setup Paging

    I removed the TGAR so it now looks like this. I didn't change the "MANO" since there are no Zones. Connected straight to Paging AMP that requires 600ohm connection. Still getting the fast Busy tone. removed TGAR by LD 16 at TGAR typed x01 TYPE RDB CUST 00 DMOD ROUT 45 DES PAGING TKTP WAT...
  13. waynehamm

    How to Setup Paging

    I have setup the Route and Trunk port using COT, PAG, and WAT and each time I dial the number I get a fast busy tone. Here is the config for WAT TYPE RDB CUST 00 DMOD ROUT 45 DES PAGING TKTP WAT SAT NO RCLS EXT DTRK NO ISDN NO PTYP ACO AUTO NO DNIS NO ICOG OGT SRCH LIN STEP ACOD 699 CPP NO...
  14. waynehamm

    No Caller ID Set shows 7925-1

    So how do I find out what I'm currently using for outside lines?
  15. waynehamm

    No Caller ID Set shows 7925-1

    GHTROUT" - I got the information that I thought was needed was from the following thread (Sorry forgot to add it) http://www.tek-tips.com/viewthread.cfm?qid=1476392&page=10 "Johnthephoneguy" - The phone lines are working so I'm not sure why the Channels say disabled. How can I tell what type...
  16. waynehamm

    No Caller ID Set shows 7925-1

    Have a Meridian Option 11 What is required to get Caller ID information? I found a related post and have posted what they requested in order to help. Location: Windsor, Ontario, Canada >ld 60 DTI000 .stat PRI* TRK LOOP 1 - ENBL FFMT/LCMT/YALMT: ESF/B8Z/FDL TRACKING SERVICE RESTORE: YES...