Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: billgray
  • Order by date
  1. billgray

    TM 3.0 Install Problem--initdb

    Thanks for the tip...that fixed it for you?
  2. billgray

    TM 3.0 Install Problem--initdb

    Trying to install TM 3.0 on Win 2K3 server, and the machine is joined to a domain. IIS is installed and was configured using the VB script from Nortel's web site The Postgre SQL install fails every time with this error: "Failed to create process for initdb: The service cannot be started...
  3. billgray

    Passing Inbound Caller ID after Transfer

    I would look at the CDR parameters that are set at the remote site...make sure that in LD 17 PARM that CLID is set to YES. If you can post one or more of the raw CDR records where the CLID is missing I might be able to help more.
  4. billgray

    Frame Slips on Tie Line

    Yep, one side is user the other side is net, IFC SL1...I've done a hundred of these, that's kind of a no-brainer at this point. Here you go. Johnpoole I'll see if I can't implement a clock board on the tie line TMDI's. DCH's: ADAN DCH 13 CTYP TMDI CARD 03 PORT 1 DES...
  5. billgray

    Frame Slips on Tie Line

    Tie line between 2 Option 11C's, TMDI cards at both ends. I'm getting incrementing SLIPD errors at both ends. Both Option 11's are clocking off of the local carrier's PRI. The LD 73 DDB and LD 60 "SSCK 0" both confirm tracking to the primary clock source. There are no slips on the local PRI's at...
  6. billgray

    Error 80011

    Trying to connect to a BCM50 using BCM Monitor, after about 1 minute BCM Monitor times out trying to connect and I get "unable to connect...error 80011". I can connect to/program the very same unit with Element Manager, no problem. I can ping my laptop from the BCM, I can ping the BCM from my...
  7. billgray

    Minimum Vintage SSC For Succession?

    Hey Folks, What's the minimum vintage SSC for Succession 3.0? Thanks!
  8. billgray

    Minimum Software Release For Rlogin?

    Hello, Can anyone tell me what minimum software release is required for rlogin? No problem to solve today, just curious for an answer if anyone knows. Thanks!
  9. billgray

    MAT004

    john--turned on the login name (LNAME) option for passwords and it fixed it. why all the other optivity sites work without it but not this one--i have no clue, and neither does our vendor. Thanks man.
  10. billgray

    MAT004

    the pbx is responding that the login/password is invalid (when i know that it's the right one!) so i am assuming the port is ok.
  11. billgray

    MAT004

    OTM isn't logging into a tty port since it's IP. we checked the pty port programming and it's ok.
  12. billgray

    MAT004

    25.30, and I have others working on the same rel.
  13. billgray

    MAT004

    Hey folks, I'm using the DBA function in OTM to collect traffic (not CDR) from multiple Meridian 1's. Over 30 of them, 11's 61's and 81's and they all work except for one, where the connect from OTM fails and the option 11 gives a MAT004 error (incorrect login/password). I can connect to the...
  14. billgray

    NTDK20CA & Ethernet

    thanks much, will check it out.
  15. billgray

    NTDK20CA & Ethernet

    Just fact checking here--is anyone aware of a reason why an NTDK20AB Option 11 SSC card would not work for ethernet? If so, what's the minimum SSC rev for ethernet? Thanks in advance.
  16. billgray

    Call Pilot Service Observe

    I can and have programmed Norstars including NAM voicemail and Cinphony but it's been a few years. I've been in telecom for 10 years, it's what I do for a living, designing & programming Avaya Definity call centers of up to 600 seats, Nortel Meridian 1 programming, etc...PRI, DS-3's, you name...
  17. billgray

    Call Pilot Service Observe

    I'm going to set up a Call Pilot 150 for ACD for a friend's small business. Like it or not, I'm going to have to "figure out" the ACD program onsite. Not a big deal, I have experience w/ Norstar. But can anyone give me a headstart on service observe? Would I just enter a feature code and agent...
  18. billgray

    PRI Issue--Option 61 & Siemens EWSD

    it's NI2...I've spoken with another telecom person who has had the same issue out of a Siemens from a different carrier (Verizon). The fix involved changing software settings in both the C.O. and PBX but she doesn't know the particulars..i will circle back with the carrier and have them check...
  19. billgray

    PRI Issue--Option 61 & Siemens EWSD

    the d channel est the rel...yep, have done a fdl...haven't status'd servce messages, next time it drops will do that...right now dsel is vod, are you suggesting voice only? lol, contract negotiations are coming...

Part and Inventory Search

Back
Top