Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. MorpheusWin2K

    Allow 911

    Yes, I would like to see about setting the residents phones to ring the nursing station extension, instead of the emergency call center. If you have any ideas, I would appreciate this. I will not be able to review until March 21st. Thanks
  2. MorpheusWin2K

    Allow 911

    I have contacted our local carrier (Verizon) and they said that our facility was not listed. They made a change request to their database and it should be correct after 7PM. Thank you all for your help. You saved me. This is a very good site. I've used it a couple of times and will probably...
  3. MorpheusWin2K

    Allow 911

    That worked like a champ - Thank You The only thing missing now is the Building ID/Caller ID. The call center indicated that all they had was the number and they should see more. She said I should call our carrier. Does this sound correct? Thank You again for your help.
  4. MorpheusWin2K

    Allow 911

    Sorry about hiding the TNS. Here is the route for the copper trunks: TN 002 0 00 00 MBER 1 TN 001 0 00 01 MBER 2 TN 002 0 00 02 MBER 3 TN 003 0 00 03 MBER 4
  5. MorpheusWin2K

    Allow 911

    I'm told that the system was set up to place all calls, local, regaional, and LD through the PRI first. The trunks are in place as a failover. The part that I'm confused about is how it used to work until a couple of months ago. Like I said in my original post. The 180 beds are all analog...
  6. MorpheusWin2K

    Allow 911

    Stat Results for the Trunk Card: STAT 2 00 = UNIT 00 = IDLE (TRK)(CO GRD) 01 = UNIT 01 = IDLE (RVSD) (TRK)(CO GRD) 02 = UNIT 02 = IDLE (RVSD) (TRK)(CO GRD) 03 = UNIT 03 = IDLE (RVSD) (TRK)(CO GRD) 04 = UNIT 04 = IDLE (RVSD) (TRK)(CO GRD) 05 = UNIT 05 = IDLE...
  7. MorpheusWin2K

    Allow 911

    Which card would it be for the XUT card. I have about 12 or 14 Analog cards, and each of them when I stat them will show all the stations as to being busy or idle. 03 = unit 03 = idle (l500) 03 = unit 04 = busy (l500) 03 = unit 05 = busy (l500) 03 = unit 06 = idle (l500) 03 = unit 07 = idle...
  8. MorpheusWin2K

    Allow 911

    The information on the version and release of the phone was taken directly from LD 22 in the switch - below is the exact printout: Version 2111 RELEASE 22 ISSUE 16 + This facility is located in Franklin Park, New Jersey. Route 0 TYPE TLS TKTP COT ROUT 0 DES COPPER TN XXX X XX XX...
  9. MorpheusWin2K

    Allow 911

    LD 86 RLI 0 ENTR 0 LTER NO ROUT 0 TOD 0 ON 1 ON 2 ON 3 ON 4 ON 5 ON 6 ON 7 ON CNV NO EXP NO FRL 1 DMI 0 FCI 0 FSNI 0 CBQ NO ISET 0 MFRL 0
  10. MorpheusWin2K

    Allow 911

    We are running an Option 11C Version 2111 Release 11 Issue 16 + in a Long Term Care facility. Our switch used to be set up so that if an analog phone (resident) placed a call to 911 it would rings the nursing station. The nurse on duty would determine the validity of the call and place 911...
  11. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    After doing my loopback test, I discovered that I needed to change out my cable, once I did, then the circuit came up and I got exactly what "johnpoole" stated I would see, the card come up and the D channel show wrong mode. This is what I have going on (I did a Stat of my D channel in LD 96...
  12. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    This is the status of both my DCH and MSDL: .stat msdl 10 MSDL 10: ENBL DCH 10 DCH000 .stat dch 10 DCH 10 : OPER RLS AUTO DES : INTERNAL .
  13. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    Below is what I get when I do a "Perform remote loop back test on loop". Is this what you wanted to know. I can not find the Errcode:030 anywhere. .rmst 5 SLFT FAILED DTI009 5 ERRCODE: 030
  14. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    What's the command to "loop the circuit back to itself"?
  15. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    OK, changing the "DTRK" to YES worked and it allowed me to create my trunk members. Now in LD 60 I can not seem to get rid of the red alarm. A test of the hardware comes back OK. The test of my loop comes back with a: DTI009 5 Errorcode: 030 I can not find an errorcode 030. The codes list...
  16. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    I can not add my trunk members in LD 14, I keep receiving: SCH2034 A digital route is required. This is what I have built: RDB TYPE RDB CUST 00 DMOD ROUT 3 DES INTERNAL TKTP TIE ESN NO CNVT NO SAT NO RCLS EXT DTRK NO ISDN NO PTYP ATT AUTO NO DNIS NO ICOG IAO SRCH LIN...
  17. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    I did not have it built that way. I went back and made those changes. Now when I try to add the route members I receive the following error: SCH4788 PRI loop is not configured with D channel (DCHI) to provide B-channels.
  18. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    I have the loop created in LD 17. I have the RDB built in LD 16. I can not seem to add the route members in LD 14. I keep receiving the following error: SCH2034 A digital route is required. Help
  19. MorpheusWin2K

    Configure 2nd PRI for Dialing between Sites

    The 1st PRI is connected to the Telco. The 2nd PRI is strictly for 4 digit dialing between sites via the Siemens RG8702 Gateway. Would I add the 2nd card to the original loop?

Part and Inventory Search

Back