Thanks, GHTROUT. it acutally was an existing code in our system that we forgot about since we haven't used it in a while.
Acewarlock, I thought I was specific enough. Will do so in the future.
Thanks you
Is there a way to block caller ID so that the called party does not see who it is from on a M2250?
I looked at the opt on att_data and thought it would be as simple as adding cls clba like on a M2616. I rarely work on the console phones and any advise would be greatly appreciated.
Thank you...
Scenario:
We have two companies utilizing the same PBX: Meridian Opt.11
Company A is: Customer group 0 in the programming
Company B is: Customer group 1 in the programming
Company B request a new block of numbers in the 3000 range. We program them w/ VM as well. All is working fine...
I'm not too sure what the technical term for this is, but, we have a client who uses the extension in the 3000 range in their offices. Calling from within the company (ext.3xxx) and inbound calls to the company (408-xxx-3xxx)is normal, but making outbound calls from the company, the last four...
bigindian65,
I tried that. deleting the VM box. it gives me the same error response:
"A system error occurred, and the user was not deleted. Try again later"
It's unusual. It is only for this particular mailbox. This mailbox does exits in the system too. Trying to add the mailbox it...
Good evening,
I am having difficulties accessing a particular number in VM. x6476. All other VM boxes I can access. View/modify, delete, etc.
Whenever I access (view/modify) this particulare VM I get this
system respones:
"A system error occurred, and the user was not modified. Try again...
trying to rollover x1234 on a type 500 analog line to x5678 on a 2616. I've changed CLS to FNA and was expecting the prompt to ask to which extension to rollowver, but it didn't. Any assistance would be greatly appreicated. Thanks.
REQ: prt
TYPE: tn
TYPE TNB
TN 4 0 7 4
SPWD
DATE
PAGE...
I need assistnace in identifying the following ports. I'm taking a guess on a few of them
TTY #05 LOGGED IN 01:17 4/4/2006
>ld 37
IOD000
.stat tty
TTY 0 : ENBL DES: SYSMON
TTY 1 : ENBL DES: TERMINAL(I assume it's dummy terminal)
TTY 2 : ENBL DES: CORE
TTY 3 : ENBL DES...
Thanks again to lretrievers and John for the assistance. Also just in case anyone is trying to set up something similar. You need to first build a DMI and RLI, both in ld 86 before setting up the LOC in ld 90. I found this out the hard way.
We have an office in NYC. To dial them, we use a 4 digit code + the last 4 digits of an individuals extenstion to call them instead of dialing 9-1-212-xxx-xxxx, etc. I'm trying to figure out the name of this feature so I can set up a similar dialing code for our MA offices. Is this called...
Good afternoon, everyone. I am curious to know if this is possible? Or if anyone is using this type of remote access connection. We are trying to connect to our Option 11 in NYC. Any advice into setting up this type of remote access would be greatly appreciated.
Thanks
I'm glad I'm not the only one that finds this request strange.
This is the first time we ever had anyone request their phones to be shut down for just a few hours and we never bothered asking why.
Thanks again john for the help. Looks like we're going to disable the loop since we know which ones belong to the client. Looks like someone will need to be here to do it at the specified time though since I don't see anyway to get it to disable at the right time.
Please have XXXXX make the following changes to the CS/FFM phones. Starting Monday October 31st our phones should only ring from 9am-5pm.
Additional phones changes-
November 2nd –our phones have to shut from 1230p-2p
November 10th- our phones should shut off at 3pm
November 17th –our phones...
Good evening,
We have a client request to have thier phones shut down between 1230hrs-1400hrs on one day and on another to have it shut down for an entire day. How will this be accomplished? Is there a way to disable a phone/tn in the PBX without outting it all together or do is this all...