  1. mattwc1

    IP 2001 DHCP Parse Error

    CS1000, Rls7.5, all phones are DHCP all same node. After a power outage in one of our buildings all of the IP 2001's and 1110e's went down and stayed down. Then it spread to the rest of our system and 2001's and 1110e's in other buildings went down. They all say DHCP Parse Error, DHCP server...
  2. mattwc1

    Site Manager 15.7.1

    Is Site Manager 15.7.1 backwards compatible with a Nortel ASN router running 15.5.1.1? 15.7.1 is the only version I can find on the Avaya site but documentation does not mention backwards compatibility.
  3. mattwc1

    CLID on IP Flex

    We are replacing PRI's with IP Flex. The IP Flex will give us a presence in other states. Customers call a local number in their state (555-444-3333) and we recieve the call on our IP Flex, 4 digit did (3333) that I will route to our operator. We can make local calls back to that state through...
  4. mattwc1

    3900 series phone callers list password reset

    Sometimes I have to issue CPWD command twice in a row and then the 3900 set will not ask for a password.
  5. mattwc1

    BCM50e red status light

    I changed the ip address, subnet mask, and default gateway on a BCM50e Rls 1. I rebooted, the new address was applied, the OAM port still works, and all other functions work, but the status light is now red. How can I get that light to turn off?
  6. mattwc1

    Back up option 11 without LD 143

    OK , I know how to do an internal back up with a data dump but can I do a back up from the Option 11 to my laptop like I do with LD 143 on newer Option 11's ?
  7. mattwc1

    Back up option 11 without LD 143

    I've backed up Option 11 systems to my laptop with load 143 for example : >LD 143 CCBR000 .XBK INFO:NAME FILE SIZE = 218880 bytes R>OK.XVR R>CCCCOK. But how do you back up an Option 11 , Rls 18 that doesn't have LD 143 or a pc card slot ? I've seen a thread that says to use BKO in LD 43 but...
  8. mattwc1

    Delete CLID entries

    I have a customer that does not want to send CLID . When I go to LD 15 CHG NET_DATA CLID NO I reply no to CLID prompt , but the switch still sends the number . If I try to delete a CLID entry LD 15 CHG CLID YES ENTRY X1 ENTRY 1 DELETED ! ENTRY BUG481 I get this BUG481 code and the...
  9. mattwc1

    CFW to external number

    OK I figured it out . All the programing was right .CFXA and CFF were in programing . Dialing out of this system (dial 9) goes out RLI 1 , Route 1 . It's a group of 18 COT trunks . I've made lots of calls out of this switch and never failed to get outside dial tone and the customer never...
  10. mattwc1

    CFW to external number

    I have a SL1 switch , with a SL1 phone TGAR 0 NCOS 6 CLS UNR CFXA Key 00 SCR XXXX DID Key 06 CFW 12 When we forward to an external local number (9 XXX XXXX) sta to sta calls will forward . External calls coming in on the DID get a pause and then a fast busy . WE can call this number directly...
  11. mattwc1

    8x24 Centrex ,new stations will not sync up

    Yes , they were the right kind of phones . I got one of them to sync up on one of the first 12 ports . Did a start up , swapped software , ports still don't sync . It's just a bad KSU . Next time I will sync phones up on every port I plan to use before I tell the customer it will work . Lesson...
  12. mattwc1

    8x24 Centrex ,new stations will not sync up

    I have an 8x24 , Centrex software , ports 101 - 112 equipped and working . I tried to add 8 new phones but they would never sync up , just flash forever . I can get on ports 101 - 112 with one of my new phones and it will sync up , but when I try 113 - 124 it will not sync up . I have replaced...
  13. mattwc1

    Meridian Mail will not reset after power outage

    I'm not shutting the system down . The power went out because of a thunderstorm , the ups was exhausted and then the system went down .
  14. mattwc1

    Meridian Mail will not reset after power outage

    On an Option 11C , if power goes out , and then comes back on , switch comes back on , but Meridian Mail will not come back on until I go to LD 48 , ENL AML 9 ACMS . Is this normal ? Is there a command that will bring Meridian Mail back up automatically after a power outage ?