Back-up and check the Temporary UDA folder after each server reboot.
This fix results in the Temporary UDA folder being reset to the default one after each reboot. This might cause unexpected behaviour if that default Temporary UDA folder is on a drive with little diskspace. We had some cube...
As no-one has posted a solution to the "The catalog's available user classes do not correspond to any defined by the Common Logon Server" issue, I will.
Just add the 'Creator' user class to the namespace that is used for autentication.
Be carefull, localized versions of Impromptu might have a...
Hi,
I'm trying the exactly same thing and managed to subtract a number of days from the AS400 system date.
SELECT DATE ({ fn CHAR({ fn CURDATE() }, USA) }) - 30 day AS START_DATE
FROM TABLE
What I can't get done is to re-format this date to YYYYMMDD format for comparison.
Thanks,
JT
Until recently I managed to run Macros through Windows 2000 "Scheduled Tasks" using the SYSTEM account.
"Scheduled Tasks" - "Advanced" - "AT Service Account" (make sure this is set to "System Account".
Then create an old-fashioned AT schedule:
at 07:00 /every:M,T,W,Th,F cmd /c C:\Macro\ACL.MCX...
That's strange behaviour indeed.
What platform / version are you running.
I have Upfront 7.1 MR1 on W2K. The # of processes in Upfront Admin and in taskmanager completely match.
Have you tried to identify which process ID's don't fugure in Upfront Admin that do show-up in taskmanager (assuming...