Thanks for the response, but I didn't quite understand it.
I think that 3310, 3320 on I/O LIM passed OK.
LIM2 and LIM3 are in "30" because they are waiting for I/O LIM to start loading them...
What bugs me is why LIM1 is showing "30", probably because of no valid REL directory...
I will try to fix this error on Monday, but it would be nice if someone advise what to expect on site and which boards I should bring as a spare parts...
It is a 3-LIM system, all LIMs are at the same location (I think that it is a multi-lim system because of the total capacity...).
Not seen...
I have a working scenario with EXL lenght of 10 digits (which is a max No of digits for EXL).
Problem is that I need to change this EXL to 13 digits.
Is there a way to do this?
My EXL contains DEST+provider access No (eg 123+1234567 - now it is 10 digits total). Provider will change his access...
As far as I`m aware, SPU (SPU4 to be exact) is used as DTMF receiver or for RVA.
I don`t understand when you say "I try to call to SPU".
I would like to know more details about this, please.
I`m sorry for noobish question.
Of course ceejay55 was right about port that should be used for connecting.
As I said (and was wrong), I was using highest tty port which is No.3
After changing to lowest tty, all is OK.
Thanks for pointing the obvious to me!
I`m aware of this problem and E/// advice, but it doesn`t make sense, cause in my case even the newly shipped 4223s are dying.
It is true that the new ones die in less quantity, but that is horrible from advertising point of view. The 3xxx series newer had any problems what so ever (you could...
Hi,
I`m trying to load the INL on to new NIU2/12.
After writing the EIC, and IP setup, I`m using FTP to copy the INL. All is OK and after a restart, MD is loading from INL (it starts from "60" and stops at "101"). So far so good, but when I try to connect, there`s no USER/PWD prompt!
As far as...
I solved the issue from the OP!
I checked the grounding on LIM 3, it was OK.
I could hear some buzzing sound coming from rg5dc, so I blocked and turned off lim 3 and replaced the board.
After starting the 3rd lim, it wouldn`t see GJUL and couldn`t start at all (2700 on lpu display).
Since I was...
@doktor
I`ve seen your instruction in one of posts regarding grounding. As I said, I will check that also, but FYI, LIMs are on different locations and were properly grounded when installed.
Thanks for support!
Did some research about LALRL, and will try it.
In the mean time I`m posting some printouts for reference:
[code]
[small]
<CADAP;
CALENDAR DATA
IDENTITY=HET
VERSION=CXP1010101/4/TSWSP04/R5A
08:48:23
FRI 13 NOV 2009
END
<ALLOP;
ALARM LOG
IDENTITY: HET
VERSION...
Thanks for instructions Daddy!
I`ve never even read about this command before, so I need to check it first (educate myself) and then try it and comment.
I`ll for sure try to do a data backup before anything else and even go for SP6.
Thanks again!
You really need to be very careful before deciding to do it your self. Get to know more about the system and I must agree with "ceejay55" - do some trainig first!
I can only tell you that my approach is - start from INL!
This maybe the slowest path, but it worked every time for me.
BR, Igor
I have 3 lims, and each one have digital, analog and DECT extensions. Connected via GS using one PCM link toward each lim.
System is TSW-SP4, HW is in LBP20 (all boards are from earlier HW release, just SW was upgraded from BC 12 to TSW).
System worked flawlessly for 2 years after upgrade and...