Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. BiscuitJack

    Adding Nortel IP Seats and 1140 IP sets

    As of Communication Server 1000 Release 7.0, new ISM limits can be activated without sysload if they are greater than or equal to the actual ISM usage in the system. Otherwise, installation of the new keycode is blocked.
  2. BiscuitJack

    Application for capturing a TNB dump

    http://www.pepedog.com/meridian/
  3. BiscuitJack

    Analog Terminal Adapter Installation on 3900 phone for Clapper Bell and or Light

    Correction to line "(Cross Connect ATA TN to ATA)" above. The ATA TN does not need to be cross connected as the ATA TN rides on the SET TN circuit wiring. The ATA TN is MUXed through the connection on the back of the phone to the ATA hardware.
  4. BiscuitJack

    Analog Terminal Adapter Installation on 3900 phone for Clapper Bell and or Light

    Must Pair SET TN with ATA TN for example: 4 0 0 0 for 3900 SET and 4 0 0 16 for ATA 4 0 0 1 for 3900 SET and 4 0 0 17 for ATA 4 0 0 2 for 3900 SET and 4 0 0 18 for ATA 4 0 0 3 for 3900 SET and 4 0 0 19 for ATA (Etcetera) Follow wiring diagram that comes with ATA (Cross Connect ATA TN to ATA)...
  5. BiscuitJack

    External call fwd

    Try HNXX of 999 if it will allow.
  6. BiscuitJack

    Avaya 1140e Blue ligt

    If you can dissolve the adhesive on the PCboard without damaging it, you can swap blue LED for the red LED.
  7. BiscuitJack

    ERR5525 Avaya's Official Stance

    [/b]CS1000 Getting ERR5525 on every incoming call from CO Doc ID: SOLN180319 Version: 3.0 Status: Published Published date: 15 Jul 2010 Updated: 27 Feb 2013 Author: admin DETAILS NORT055179 PROBLEM CLARIFICATION Fact: Communication Server 1000 Succession 3.0 Meridian 1 NI2 Symptom: Getting...
  8. BiscuitJack

    One Way Speech Path IP2033 CS1000E

    thread798-1592756 I have the exact same problem with the previous thread listed above. I didn't see a resolution to the previous thread so I'm starting a new thread to rehash. The scenario is a CS1000E 5.5...
  9. BiscuitJack

    CS1000E 5.0 Virtual Office Question

    I figured it out..... The book says Phantom Tn's but in reality you have to assign any consecutive Virtual Tn's. I was trying actual Phantoms and it doesnt like it.
  10. BiscuitJack

    CS1000E 5.0 Virtual Office Question

    I have DID profiles all with VO allowed VOLA and VOUA assigned to phones. I am using IP1140E and 1120E phones. When I want to hotdesk using virtual office feature between office phones and once I have already logged onto another phone. The previous phone shows in the display "Logged Out" and...
  11. BiscuitJack

    [b]BFS key not Showing busy/idle status of boss's phone[/b]

    I checked the DNB and it is clean...I haven't started over with new TN's yet because I wanted to experiment with it a little more. Here is what I found: If I make CLS BFED on one set but the other set is CLS BFEA then the busy/idle status works and it doesn't matter which phone has BFEA and...
  12. BiscuitJack

    [b]BFS key not Showing busy/idle status of boss's phone[/b]

    We have CS1000E 4.5 and two phones are programmed one as the Boss's phone and the other as the Secretary's phone. We are using MCR keys on both sets. The secretary's phone has a BFS key with the Boss's Tn. The BFS key is not indicating the idle/busy status of the boss's phone like the "Boss...
  13. BiscuitJack

    PRI problem between CSE1000 and DMS 500

    Hey Lavrunin, We were on the Verizon network before and everything was going out fine like you. We thought the same thing when we moved our service to AT&T that the carrier needed to conform to us but AT&T our new provider told us that we had to change so good luck on getting Level 3 to bow...
  14. BiscuitJack

    PRI problem between CSE1000 and DMS 500

    Also noticed this: CDN_Digits : 6314892 CDN_TON : NATIONAL CDN_NPI : E164 CGN_Digits : 2022543600 CGN_TON : NATIONAL CGN_NPI : E164 Level 3 should not receive your calling DN as NATIONAL because E164 NATIONAL requires 10 digits to conform to the...
  15. BiscuitJack

    PRI problem between CSE1000 and DMS 500

    We are using NI2 CS1000E 4.5 with PRI's. We were having trouble getting calls to cross the Level 3 network to Vonage users as they were being rejected. Level 3 said we were not following the E164 rules of engagement. We were sending calls out: CALLING #:8323370999 NUM PLAN: E164 TON: INTL...
  16. BiscuitJack

    CS1000 5.0 VGMC 32S Faceplate error W039

    We have a CS1000 5.0 VGMC 32S that gets a Faceplate error of W039. At this point the channels lock up and we have to reseat the card to clear problem. Over time the problem returns and we perform the same solution.
  17. BiscuitJack

    Error SRPT189 Not enough band width for call b/w 0x 20xxx & 0x 9cxxx

    Do you have a Signaling Server? If you do you can look at the Zone configuration there and make changes much easier. If not, go back to ld 117 and do a "=>prt ?" to see what commands are available to you. You should be able to see a list of all the zone commands. You can also look at "=>chg ?"...
  18. BiscuitJack

    Electronic Brandlining

    Nevermind. I found the answer on another post.
  19. BiscuitJack

    Error SRPT189 Not enough band width for call b/w 0x 20xxx & 0x 9cxxx

    Try increasing your bandwidth threshhold on your bandwidth zone in LD 117 and see if that stops your error message. The bandwidth listed in your zone should match the available bandwidth on your data network. If you have a gigabyte network then your zone bandwidth should be 1000000. Use "=>prt...

Part and Inventory Search

Back
Top