...: No
Language : English
EXTENSION INFORMATION
Extn SS/PP Type
50 4/ 6 T/R
Button 34 *21 Blank Status None
Button 33 *21 Blank Status None
Button 32 *21 Blank Status None...
I had tried to assign lines to the night service group but winspm gives me the error sound and refuses to do it. The processor identifies as "Legend 2.1 V 4.0". From the Rel 5.0 System Programming Manual:
"A calling group can also be assigned to a Night Service group. This applies only to...
Merlin Legend R2 processor, key system mode: the last of four LS lines (804) into a 408 module is used for the fax machine; the fax extension is set to auto line select to 804 but is not set as a fax line in 'options' in order to prevent fax activity from setting the MWIs on the (ATL) phones...
This question from 2005 doesn't really have an answer; I intend to do the same with with an asterisk backend and need a solution. For the moment I have two legend 7.0 systems networked over PRI for experimentation and MWI isn't working on the remote systems when using FEAT 53 to send.
Help much...
Thanks, sorry I missed the Sub-A settings - that fixed it.
BTW, what is/are the command chain(s) for this item?:
SYSTEM DEFAULT CLASS OF RESTRICTIONS (TIE)
Restriction : OUTWARD RESTRICTED
ARS Restriction Level: 3
Allowed Lists :
Disallowed Lists :
Even...
Thanks for your reply. No luck after making those changes.
The error tone is identical to what is heard when dialing an
invalid extension. I also lowered the FRL value on a few routes
in case that was an issue (which will explain the discrepancy in
the printouts).
Configuration printouts...
I am experimenting with two networked Legend R7.0 V10.0 systems
connected with a T1 crossover cable between 100D(CD) cards.
Currently I have UDP set up so that extensions on each system
appear as local extensions on the other system. System A has
one POTS line for use by both systems (System B...
The audio file data does not conform to any of the containers for gsm according to RFCs and other authoritative sources, for example RFC 1890 and 3351 describe a frame of 33 octets each beginning with the upper nibble of the first octet having the value 0xd; example gsm sound files do indeed...
Been futzing with 'sox' trying to play some of the files on the drive assuming they are full-rate gsm (RPE—LTP) but getting
"result too large" errors. Guessing 16 bit precision. Tried little and big endian byte order. Sample rate isn't relevant to scaling but guessing 13kbps. It would be great...
Processor resources according to R3 Programming Manual:
68000 microprocessor, 256Kbytes RAM, 512Kbytes ROM
Voice encoding method: Regular Pulse Excitation—Long Term Prediction (RPE—LTP) Linear Predictive Coder
Digital Signal Processor (DSP), 16 bit
Perhaps 512kB are sufficient to hold the...
Surely someone out there has investigated the contents of the hard disk in various Partner Mail VS versions or has some knowledge of the operating software and data organization. I was surprised to find that the disk from a Partner Mail VS R3.0 (350MB Conner 2.5 inch) is formatted FAT16 under...
I revised my diagram (see link above) to move the AC (phase)
pin closest to the PCB one position to the left since on some
power supplies the pin I specified originally is missing; both
pins are connected together however.
The system is now up and running using the connections
described in my...
Thanks Jim!
Here is my take on the connector from the power supply inside a 206E module, looking into the connector, with male pins:
NOTE: ASCII art doesn't render properly with the proportional fonts used on this forum -- please copy and paste into a text editor with a fixed-width font --...
...trying to quickly test some gear and not wait for delivery of a power cord...
Would anyone care to drag out an ohmmeter and document the cord, please?
Just acquired a Partner Plus without power cord; I would dearly appreciate a description of the connector and its pinouts (e.g. looking into the jack on a module please describe the pins by position and their connection). I presume that two pins take 120VAC (I'm in the USA), and I would simply...
Thanks. Working now in key mode as per your instructions above.
1. assign line/trunk to the extension:
system prog->extensions->lines/trunks
2. centralized programming->enter extension->dialpad->*14->click on line button->**14
3. test phone (outside line dialtone immediate when going offhook)
For the moment I am still in 'key' mode -- I tried ALS in Centralized Programming but my entries were ignored (didn't appear on any buttons). According to the feature reference, single line phones should permit ALS with an outside line. I tried deleting
all lines/trunks from the extension...
NOTE: the hotline approach is simply assigning the digit 9 as the first (01) personal speed dial number and setting the extension as hotline from winspm.
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.