Looking for P-Series engineer with 10 + years experience in hardware maintenance to join a team of engineers.
Opportunity is in Sydney Australia. If you would like a sea change
in this small Australian city please reply ASAP.
Log in to commandview then add /fieldservice to the line.
Once in fieldservice you should be able to save MLD.
The config of the system is stored on the quorum disks which from memory will be a minimum of 5 drives of the default disk group.
Thanks for the reply.
I need to be able to view the raw data in a presentable and meaningful fashion. Is there a way to do this.
Looking through the xml output I cannot identify the information related to the server info.
I have a DSA xml file that was created using the portable version of DSA. How can I view the data in HTML format similar to what the installable version presents?
TIA..
Hi Toygal.
If you haven't completed this task by now can I give my 2 bob's worth.
Boot the ServeRaid CD. Upgrade the BIOS/Firmware and configure your Raid Sets.
Boot the ServerGuide CD which asks a lot of questions and from here continue on to install the OS.
Pretty straightforward; by using...
I recently purchased an EV5000 2C2D to muck around with and would like to know where I could get the Service Manual from. Does anyone know the link to this so I can download it ? TIA
Thanks for your help. I gave up trying to install Solaris
on the x3650 at this stage. I have installed in on some Blades and am checking this out. Will look at the x series issue a little later.
Trying to install Solaris 10 on an X3650 (7979) and am getting pcplus :nmi interupt and the server reboots during install,around the time when asking for time locale.
I have disabled the reboot on NMI in BIOS but am unable to go any further at this stage due to reboots.
Assistance with a...
Hi EDSYS,
If you run DSET on the servers you should be able to ascertain which one is causing the problem from the fan section.
See the link for DSET...
Download SUU 4.5 from Dell. Create the CD and run from Windows.
http://supportapj.dell.com/support/downloads/download.aspx?c=ap&l=en&s=gen&releaseid=R111677&SystemID=PWE_FOS_XEO_2650&os=WNT5&osl=en&deviceid=9796&devlib=0&typecnt=1&vercnt=3&formatcnt=1&fileid=145877
I see you have been inundated with replies. How did you go with this?
You would use Array manager to create a new virtual disks that are installed with the system powered on.
Do a rescan from array manager once they are spinning then create the Virtual disk
<F10> only gets you into the system partition if installed.
<F8> for newer servers.
Try Smartstart 5.4 or check to see if you can boot
off a Windows CD. You may just have a faulty drive.
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.