Hi,
Is it possible to remotly record the OGM501 via DISA?
From the DISA Menu i've tried *47 extn pin and get dial tone,
but then when I try *362 501 to playback the existing OGM I get a reorder tone.
Regards
Isinor
Hi,
I'm trying to create a basic DISA phone menu with 2 options - option 0 to operator, option 1 to leave a message on SVM 591
Option 1 should call VPS 678 with both FWD and Intercept set to 591
SVM is working OK for another extension with FWD to 591
OGM is playing OK and Option 0 works fine...
LCR can be used to do this.
This is close to what you will have to do, assuming that you are using Exchange Numbers A=71, B=72, C=73 for networking, public network from C is DEST 79 and LCR access is set to 9.
In Exchange A - Setup LCR and add this entry
LCDDI:TAB=ENT,ENTRY=9,TRC=1,PRE=7379...
Hi
Try setting the call type with OPCTS, you might need to tweak CALT 5, 6 or 7 depending the the route configuration.
OPCTS:CORG=xx,CALT=5,ROU=rr;
Regards
Isinor
Hi,
The 'Customer Group' might be able to do this... if you have less than 250 co(trunks)
More info in ALEX \Solution Documents\Customer Group
EXCUC:DIR=...,CUST=1;
KSCUC:DIR=...,CUST=1;
RODDI:DEST=...,CUST=1,ETC...;
Regards
Isinor
...access carriers.
Route 1 also used for indirect carrier access via 1866.
You most likely need to free up some numbers to achieve this.
/* Assign a number for LCR */
NANSI:NUMTYP=LC,NUMSE=9;
/* set access to DEST codes */
LCDDI:TAB=FDT,FRCT=1,PRE=701;
LCDDI:TAB=FDT,FRCT=2,PRE=702...
...9 is the access code to PSTN, that route 1 is DEST=701 and route 8 is DEST=702. You most likely need to free up some numbers to achieve this.
/* Assign a number for LCR */
NANSI:NUMTYP=LC,NUMSE=9;
/* set access to DEST codes */
LCDDI:TAB=FDT,FRCT=1,PRE=701;
LCDDI:TAB=FDT,FRCT=2,PRE=702...
Hi,
The operator can do this is if PARNUM 57 is set to 1 (The PABX operator is allowed to execute disconnection of the third party) and the extension SERV is open for intrusion.
To print...
ASPAP:PARNUM=57;
To Change
ASPAC:PARNUM=57,PARVAL=1;
Regards
Isinor
Hi,
You can create an alarm extension using any analogue extension...
This will allow up to 8 people in a conf… you might need to switch off conf tone to make it usable.
SPEXI:DIR=..., OPT=E;
It’s not as good as pucka solution but it may help.
Regards
Isinor
Hi,
You call allow HG Members to use Group Follow Me, in the UK the code is *24* Group Number * Dest #
Digit 6 in SEL of the hunt group controls if HG Members can use this code.
Regards
Isinor
Hi,
Yes... You need some call logging software to help get at the report your after.
When settings up CIL one of the commands allows LOGFAL and LOGABN
CLOHI:FILE=,FORM=,DMPSIZ=[,DISCR=][,LOGABN=][,LOGFAL=][,HRTBT=];
Log failed calls. Provides option to log or not to log failed calls (calls...
Hi,
Thanks... but strange, because if you look at the print... Why 2 rejected calls... didn’t they use CHO=2
Also CUST=2,CHO=1 (No Default Route Choice) only has 3 CALL ATTEMPTS and 3 TRUNK SEIZURES not 53 and 50.
On my print for CUST=1,CHO=0
CALL ATTEMPTS = 39454
TRUNK SEIZURES = 12986...
Hi,
Why is there such a large difference between CALL ATTEMPT and TRUNK SEIZURES..?
lctmp:dest=707;
LEAST COST TRAFFIC MEASUREMENT DATA
TIME = 11:12:10 19JUL07
DEST CUST CHO CALL ATTEMPTS TRUNK SEIZURES
707 2386 2025
1...
Hi Daddy,
MD110 BC13 is what any sensible person would call it... But I thought that the MD110 is dead... it's re-branded by Ericsson to be the MX-One V2 Telephony Switch. Is that right or am I & my Ericsson contact loosing grip.
Regards
Isinor