has anyone configured a Cisco Unified Border Element (CUBE) to connect sip trunks between a SV8300 and a Avaya CS1000?
Any assistance is greatly appreciated thanks in advance!
[americanflag] Go Army!
Tek-TIP Member 19,650
CCNP, CCNA, Net+, Sec+ etc etc
The circuits goof then... Did you verify that your using hdlc or ppp on both routers?
Also I'm wondering it could be a clocking issue.
example
!
network-clock-participate slot 1
network-clock-participate wic 0
network-clock-participate wic 1
network-clock-participate wic 2...
Question 1: You will connect to a swithport and use a WAN ip address given to you by your provider, Given this has a internet connection and not a point to point solution.
Question 2:Is this a mpls type service? Some how the two bounded T1's need to interconnect. If so you will obtain ip's to...
Do you have access to the circuit? What errors are on the circuit card (NIU)?
Sh interface serial0/0:1 to verify no loops on the circuit.
Also verify both ends are setup with HDLC or PPP! They must match.
[americanflag] Go Army!
Tek-TIP Member 19,650
IF both sides are hdlc it will work just fine.
Reset the card on the circuit (NIU) just pull it out and replace it.. This will clear a circuit loop.
Clear your counters and monitor the interface.
[americanflag] Go Army!
Tek-TIP Member 19,650
This may help!
http://www.cisco.com/en/US/prod/collateral/voicesw/ps6788/phones/ps10326/data_sheet_c78-584412.pdf
[americanflag] Go Army!
Tek-TIP Member 19,650
Have you thought about AutoQos?
Check out this web site.
http://www.cisco.com/en/US/tech/tk543/tk759/technologies_white_paper09186a00801348bc.shtml
[americanflag] Go Army!
Tek-TIP Member 19,650
From the manual: Some actions might not be supported in both the input and output direction. CBWFQ can be performed only on packets EXITING the interface.
So the answer is you can place them on the input and output. It is determine by what you are trying to accomplish.
[americanflag] Go...
Does anyone know how to factory default a CP-500 (524sg)
VoIP telephone? The problem is that is will not load, the lights remain on and will not initialize. I know that you can reset if your phone is active but I do not get that far.
[americanflag] Go Army!
Tek-TIP Member 19,650
Have your local provider run a traffic study on the PRI's.
I would find it rather odd that with 12 PRI's, thats 276 lines that you would have any trouble.
Do you really have that many lines or is this a fractional pri with 12b channels?
[americanflag] Go Army!
Tek-TIP Member 19,650
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.