Customer has analog trunks on a MICS. Currently trunks appear and ring only on a couple of phones, flash vmail answers after 2 rings.
After 5pm, when office staff leaves, the owner thinks he should have the ability to direct all incoming calls to his phone with a button.
Lines only appear on...
Some of my 9508s will go dark, some will not. I need them all to go dark, the Auto return is set to 60 seconds. Doesn't seem to make a difference. R11 system, essential.
You can shut it off and swap the cards yes and no programming needed. there is always a chance of losing programming but I would say you have little choice.
...start with no prefix. Connected quickly. On the new IP 500V2 A, trunk is also loop start. I added prefix but found it worked a little faster (seemingly) using a Dial short code and dialing *. Still takes about 2 seconds for the phone to show 'Connected' so maybe that is the await dial tone...
I have two identical Partner R6 308 processors. Both have SOE written at the end of the part number on the sticker. One will work with a 5 slot and a 308EC, the other will turn off the 308EC every time. Doesn't make sense to me.
...on a trunk port. Line appearance on all phones. Paging worked immediately. Now on 406ATM on IP 500V2A, there is a delay. I put in a short code *60 to line group 10 and dial * to get the unit to respond. We still wait about 2 seconds then see Connected on the phone display then paging...
You know I put in the user group short code 91N Line Group 1 and I think I was sending an extra 1 to the telco causing an error message. Was that my problem? I think so. I do not have two different ARS tables. I will have to try again Monday.
Customer has R11, analog trunks, in standard mode, we dial 9 for an outside line. I need a select group of extension when they dial nine to go out line pool 1, rather than line pool 0. Can/should that be done from user groups/short code? What would you recommend?
Well here in the office with 2-3 phones it works ok, at the customer with 15 -16 (20 req'd) phones it will not work. it resets, locks up and basically shuts off. A similar equipped 2100 works just fine. even with no trunks and no lan attached, it's useless.
If I swap out the power supply is...